Chapter 7 · Alternating Current

7.3 Power in AC Circuits and the Transformer

Only the resistance in an AC circuit takes energy on average: the power is $P=VI\cos\phi$, and the part of the current out of step with the voltage is wattless. Transformers change AC voltages with almost no loss, which is why power travels at high voltage.

Large factories in many countries pay a penalty on their electricity bill if their "power factor" is too low — even when they use exactly the same number of kilowatt-hours as a neighbour. Why should a utility care how the energy is used? Because an electric motor full of coils draws a current that is partly out of step with the voltage. That part of the current delivers no energy on average, yet it flows through every cable, transformer and generator between the power station and the factory and heats them all. The cure — banks of capacitors — follows directly from the phasors of Section 7.2.

In this section we find the average power in an AC circuit, $P=VI\cos\phi$, define the power factor $\cos\phi$ and the wattless current, and then turn to the device that makes AC the world's choice for power networks: the transformer. We see how a pair of coils on an iron core steps a voltage up or down, what limits its efficiency, and why sending power at high voltage cuts the energy wasted in the transmission lines.

Power in an AC Circuit

Let the source voltage be $v=v_m\sin\omega t$ and the current $i=i_m\sin(\omega t+\phi)$. The instantaneous power delivered by the source is $$p=vi=v_mi_m\sin\omega t\,\sin(\omega t+\phi).$$ Using $2\sin A\sin B=\cos(A-B)-\cos(A+B)$, $$p=\frac{v_mi_m}{2}\left[\cos\phi-\cos(2\omega t+\phi)\right].$$ The second term oscillates at twice the supply frequency and averages to zero over a cycle. The first term is constant.

📐 Result 7.8 — Average power in an AC circuit

The average power taken by a circuit in which the current differs in phase from the voltage by $\phi$ is $$P=\frac{v_mi_m}{2}\cos\phi=VI\cos\phi,$$ with $V$, $I$ rms values. For a series LCR circuit $\cos\phi=\dfrac RZ$, so $$P=I^2Z\cdot\frac RZ=I^2R:$$ all the average power is dissipated in the resistance.

📘 Definition 7.9 — Power factor
The power factor of an AC circuit is $\cos\phi$, where $\phi$ is the phase difference between the current and the voltage. It is the ratio of the average power $P$ to the product $VI$ (the "apparent power", measured in volt-amperes, VA): $$\cos\phi=\frac{P}{VI}.$$ For a series LCR circuit $\cos\phi=R/Z$. It lies between $0$ and $1$.

The four important cases:

The instantaneous power $p$ is negative for part of every cycle whenever $\phi\ne0$: during those intervals the coil or capacitor hands stored energy back to the source.

✏️ Example 1 — Power in the circuit of Section 7.2
In Example 1 of Section 7.2, $R=30\ \Omega$, $X_L=80\ \Omega$ and $X_C=40\ \Omega$ were in series across $200$ V, giving $Z=50\ \Omega$ and $I=4.0$ A. Find (a) the power factor, (b) the average power, two ways, (c) the apparent power.
(a) Power factor $\cos\phi=\dfrac RZ=\dfrac{30}{50}=0.60$ (lagging, since the circuit is inductive).
(b) Power $P=VI\cos\phi=(200)(4.0)(0.60)=480$ W. Check: $P=I^2R=(4.0)^2(30)=480$ W ✓.
(c) Apparent power $VI=800$ VA. The source and wires carry the current for $800$ VA, but only $480$ W is used.
✏️ Example 2 — Resistor or choke?
A lamp rated $60$ W, $120$ V is to be run from a $240$ V, $50$ Hz supply. Treat the lamp as a fixed resistor. (a) What series resistor would do the job, and how much power does it waste? (b) What pure inductor (a "choke") would do it instead, and how much power does that waste? (c) What is the power factor of the whole circuit in each case?
Lamp $I=\dfrac{P}{V}=\dfrac{60}{120}=0.50$ A; $R_\text{lamp}=\dfrac{120}{0.50}=240\ \Omega$.
(a) Resistor It must drop the other $120$ V at $0.50$ A: $R=240\ \Omega$, wasting $I^2R=60$ W — as much as the lamp uses.
(b) Choke The voltages add as phasors: $V_L=\sqrt{240^2-120^2}\approx208$ V. So $X_L=\dfrac{208}{0.50}\approx416\ \Omega$ and $L=\dfrac{416}{2\pi(50)}\approx1.32$ H. A pure inductor takes no average power: nothing is wasted.
(c) Power factor With the resistor: $\phi=0$, $\cos\phi=1$ ($P=VI=120$ W). With the choke: $\cos\phi=\dfrac{R}{Z}=\dfrac{V_R}{V}=\dfrac{120}{240}=0.50$ ($P=VI\cos\phi=60$ W, all in the lamp). This is why chokes were used with fluorescent tubes; a real choke has a little resistance and wastes a few watts.

Wattless Current and the Power Factor

Draw the current phasor $\mathbf I$ at angle $\phi$ to the voltage phasor $\mathbf V$ and split it into two perpendicular components. The part $I\cos\phi$ along $\mathbf V$ is in phase with the voltage and carries all the power, $V(I\cos\phi)$. The part $I\sin\phi$ is $90^\circ$ out of phase with the voltage — like the current in a pure inductor or capacitor — and carries none.

📘 Definition 7.10 — Wattless current
The wattless current is the component $I\sin\phi$ of the current that is $90^\circ$ out of phase with the voltage; it contributes nothing to the average power. The in-phase component $I\cos\phi$ is the active (power) component, and $P=V(I\cos\phi)$.

Wattless current is not harmless. It flows through the supply cables and the generator windings and heats them ($I^2R$ depends on the whole current), and for a given power a small $\cos\phi$ means a large current $I=P/(V\cos\phi)$. Electric motors, welding sets and old fluorescent fittings are inductive and can have power factors of $0.6$–$0.8$. Utilities therefore ask large customers to keep $\cos\phi$ close to $1$, usually by connecting capacitors across the supply (see the 🚀 box).

✏️ Example 3 — A motor's current, split in two
A motor draws $10$ A from the $230$ V mains with a power factor of $0.80$ (current lagging). Find (a) the average power, (b) the active and wattless components of the current, (c) the current that would be needed to deliver the same power at unit power factor.
(a) Power $P=VI\cos\phi=(230)(10)(0.80)=1840$ W $\approx1.8$ kW.
(b) Components $\cos\phi=0.80\Rightarrow\sin\phi=0.60$ ($\phi=36.9^\circ$). Active: $I\cos\phi=8.0$ A. Wattless: $I\sin\phi=6.0$ A. Check: $\sqrt{8.0^2+6.0^2}=10$ A ✓.
(c) Unit power factor $I=\dfrac{P}{V}=\dfrac{1840}{230}=8.0$ A. The wattless $6.0$ A raises the current by $25\%$ and the heating in the supply cables by a factor of $(10/8)^2\approx1.56$.
Check Interactive 1 opens on this motor: $P=1840$ W, active $8.00$ A, wattless $6.00$ A.
✏️ Example 4 — Power around resonance
For the circuit of Section 7.2, Example 3 ($R=20\ \Omega$, $L=0.10$ H, $C=10\ \mu\text{F}$, $100$ V), find the power factor and the average power (a) at resonance, (b) at the half-power angular frequency $\omega_2\approx1105$ rad/s, (c) at $50$ Hz, where $Z\approx288\ \Omega$.
(a) Resonance $Z=R$: $\cos\phi=1$, $P=\dfrac{V^2}{R}=\dfrac{100^2}{20}=500$ W.
(b) Half-power $Z=\sqrt2R$: $\cos\phi=\dfrac{1}{\sqrt2}\approx0.71$; $I=\dfrac{5.0}{\sqrt2}\approx3.54$ A; $P=I^2R=250$ W — half, as the name says. Check: $VI\cos\phi=(100)(3.54)(0.707)\approx250$ W ✓.
(c) 50 Hz $\cos\phi=\dfrac{20}{288}\approx0.070$; $I=\dfrac{100}{288}\approx0.348$ A; $P=I^2R\approx2.4$ W. Far from resonance almost all the current is wattless.
Interactive 1 — The Power-Factor Lab

A load on the $230$ V mains draws an rms current $I$ at phase angle $\phi$ (negative: current lags, as in a motor; positive: current leads). Left: the current phasor split into its active part $I\cos\phi$ (green) and wattless part $I\sin\phi$ (amber). Right: the instantaneous power $p=vi$ over two cycles — green where the load takes energy, red where it gives energy back — and its average $P$. The defaults are Example 3. Play sweeps $\phi$.

10−36.9
power factor $\cos\phi$—
$P=VI\cos\phi$—
apparent power $VI$—
active $I\cos\phi$ / wattless $I\sin\phi$—
numerical mean of $p$—

The Transformer

A transformer is two coils wound on the same core of soft iron: the primary, with $N_p$ turns, connected to the AC supply, and the secondary, with $N_s$ turns, connected to the load. The alternating current in the primary sets up an alternating magnetic flux in the core, and the iron guides almost all of that flux through the secondary as well. By mutual induction (Chapter 6) the changing flux induces an emf in every turn of both coils.

Suppose (i) all the flux $\Phi$ through each turn of the primary also passes through each turn of the secondary (no flux leakage), and (ii) the coils have negligible resistance. Each turn then has the same induced emf $-d\Phi/dt$, so $$\varepsilon_p=-N_p\frac{d\Phi}{dt},\qquad \varepsilon_s=-N_s\frac{d\Phi}{dt}.$$ With no resistance the primary emf balances the applied voltage, $v_p=-\varepsilon_p$, and on open circuit the secondary voltage is $v_s=-\varepsilon_s$. Dividing, $\dfrac{v_s}{v_p}=\dfrac{N_s}{N_p}$ — at every instant, and therefore for rms values too. If, in addition, (iii) no energy is lost, the power drawn from the supply equals the power delivered to the load: $V_pI_p=V_sI_s$.

📘 Definition 7.11 — Transformer
A transformer is a device that changes an alternating voltage, using two coils (primary and secondary) wound on a common iron core and coupled by mutual induction. It is a step-up transformer if $N_s\gt N_p$ (output voltage larger than input) and a step-down transformer if $N_s\lt N_p$. The ratio $N_s/N_p$ is the turns ratio.
📐 Result 7.9 — The ideal transformer

For an ideal transformer (no flux leakage, no winding resistance, no energy losses in the core), $$\frac{V_s}{V_p}=\frac{N_s}{N_p},\qquad \frac{I_s}{I_p}=\frac{N_p}{N_s}.$$ Stepping the voltage up by some factor steps the current down by the same factor, so $V_pI_p=V_sI_s$. A transformer does not work with a steady (d.c.) supply: a steady current gives a steady flux and induces no emf.

A transformer is not a source of free energy: a step-up transformer raises the voltage only by lowering the current. The secondary current is set by the load ($I_s=V_s/Z_\text{load}$), and the primary then draws just enough current to supply that power.

Energy losses in real transformers. Large transformers reach efficiencies above $95\%$, but some energy is always lost:

The efficiency of a transformer is $\eta=\dfrac{\text{output power}}{\text{input power}}=\dfrac{V_sI_s}{V_pI_p}$ (for loads with power factor close to 1).

✏️ Example 5 — A step-down transformer
A transformer reduces the $230$ V mains to $11.5$ V for a low-voltage lamp. Its primary has $4000$ turns. (a) How many turns does the secondary have? (b) The lamp draws $2.0$ A. Find the primary current if the transformer is ideal. (c) Find the primary current if the efficiency is $90\%$.
(a) Turns $N_s=N_p\dfrac{V_s}{V_p}=4000\times\dfrac{11.5}{230}=200$ turns (turns ratio $1:20$, step-down).
(b) Ideal $I_p=I_s\dfrac{N_s}{N_p}=\dfrac{2.0}{20}=0.10$ A. Check: $V_pI_p=23$ W $=V_sI_s$ ✓.
(c) 90 % efficient Output $23$ W needs input $\dfrac{23}{0.90}\approx25.6$ W, so $I_p=\dfrac{25.6}{230}\approx0.111$ A. The extra $2.6$ W heats the transformer.

Transmitting Power at High Voltage

A power station must send a power $P$ to a distant town along lines of total resistance $R_\text{line}$. The current in the lines is $I=P/V$, where $V$ is the transmission voltage (taking the power factor as $1$), and the power lost as heat in the lines is $I^2R_\text{line}$.

📐 Result 7.10 — Loss in a transmission line

Sending a power $P$ at voltage $V$ through lines of resistance $R_\text{line}$ wastes $$P_\text{loss}=I^2R_\text{line}=\frac{P^2R_\text{line}}{V^2}.$$ For a given power and line, the loss is inversely proportional to the square of the transmission voltage: raising $V$ ten times cuts the loss a hundred times.

This is the reason for alternating current. Generators produce a few kilovolts to a few tens of kilovolts; step-up transformers at the power station raise this to $220$ kV, $400$ kV or $765$ kV for long-distance lines; a chain of step-down transformers then lowers it to $33$ kV, $11$ kV and finally $230$ V for homes. A d.c. system cannot change its voltage so simply, which is why the AC grid won the "war of the currents" at the end of the nineteenth century.

✏️ Example 6 — Why step the voltage up?
(Illustrative values.) A small generating plant produces $110$ kW at $440$ V for a village $10$ km away. The two line wires together have a resistance of $0.40\ \Omega$. Find the current and the power lost in the line (a) if the power is sent at $440$ V, (b) if a transformer with turns ratio $1:25$ first steps the voltage up. Take the transformer as ideal and the power factor as $1$.
(a) At 440 V $I=\dfrac{110\,000}{440}=250$ A; $\ P_\text{loss}=(250)^2(0.40)=25\,000$ W $=25$ kW — about $23\%$ of the power. The voltage drop along the line, $IR=100$ V, is also unacceptable.
(b) At 11 kV $V=25\times440=11\,000$ V; $I=\dfrac{110\,000}{11\,000}=10$ A (or $250/25$); $\ P_\text{loss}=(10)^2(0.40)=40$ W — about $0.04\%$.
Ratio The voltage went up $25$ times, the loss went down $25^2=625$ times ($25\,000/40=625$ ✓).
Check Interactive 2 opens on this plant: ratio $25$, line current $10.0$ A, loss $40$ W.
⚠️ Common mistakes with AC power and transformers

1. Writing $P=VI$ for every AC circuit. $P=VI\cos\phi$; $VI$ is only the apparent power.

2. Using $P=I^2Z$. Only the resistance dissipates energy: $P=I^2R$.

3. Thinking a step-up transformer gives more power. It raises the voltage and lowers the current; at best $V_sI_s=V_pI_p$.

4. Inverting the current ratio. $\dfrac{I_s}{I_p}=\dfrac{N_p}{N_s}$ — the high-voltage coil carries the small current.

5. Using $V^2/R_\text{line}$ for the line loss with the transmission voltage. The voltage across the line itself is $IR_\text{line}$, not $V$. Use $I^2R_\text{line}$ with $I=P/V$.

Interactive 2 — Transformer and Transmission Line

A $440$ V generator sends power through a step-up transformer (turns ratio $1:n$) and a line of resistance $R_\text{line}$ to a town. Choose the turns ratio, the power sent and the line resistance, and an ideal or a $96\%$-efficient transformer. The line glows with the power it wastes; the graph shows the percentage lost in the line against transmission voltage, $P_\text{loss}/P=PR_\text{line}/V^2$. The defaults are Example 6 (illustrative values). Play sweeps $n$.

251100.40
line voltage $V_s=nV_p$—
primary / line current—
line loss $I^2R_\text{line}$—
transformer loss—
delivered to town—
🚀 Beyond the board syllabus (JEE Main · NEET · JEE Advanced) — power-factor correction and the power triangle

Not required by the CBSE syllabus. Power in AC circuits and wattless current are listed by JEE Main and NEET, and JEE Advanced lists LCR circuits with a.c. sources; the power triangle and power-factor correction are applications that no syllabus names.

Multiply the sides of the current triangle ($I\cos\phi$, $I\sin\phi$, $I$) by $V$ and you get the power triangle: the real power $P=VI\cos\phi$ (watts), the reactive power $VI\sin\phi$ (often quoted in "volt-ampere reactive", var) and the apparent power $VI$ (VA), with $(VI)^2=P^2+(VI\sin\phi)^2$.

Correcting the power factor. An inductive load's wattless current lags the voltage by $90^\circ$; a capacitor connected across the supply draws a current $V\omega C$ that leads the voltage by $90^\circ$. If the two are equal they cancel in the supply lines, which then carry only the active current. For the motor of Example 3 ($230$ V, $50$ Hz, wattless current $6.0$ A) we need $V\omega C=6.0$ A: $$C=\frac{6.0}{(230)(2\pi\cdot50)}\approx8.3\times10^{-5}\ \text{F},$$ that is, about $83\ \mu\text{F}$. The line current then falls from $10$ A to $8.0$ A and the power factor seen by the supply rises to $1$, while the motor itself is unchanged. Industrial plants install switched capacitor banks to do this as their load varies.

Exercises

I
Power and power factor.
  • 1 A circuit draws $5.0$ A from a $220$ V supply, with the current lagging the voltage by $60^\circ$. Find the average power.
  • 2 Find the power factor of a series circuit with $R=30\ \Omega$ and $X_L=40\ \Omega$.
  • 3 A $40\ \Omega$ resistor and a capacitor of reactance $30\ \Omega$ are in series across $100$ V. Find the current, the power factor and the average power. Is the power factor leading or lagging?
  • 4 A $0.50$ H coil of negligible resistance is connected to $220$ V, $50$ Hz. Find the current and the average power.
  • 5 What is the power factor of a series LCR circuit (a) at resonance, (b) at a half-power frequency?
  • 6 A $2.0$ kW heater and a $2.0$ kW motor (power factor $0.80$) are each connected to the $230$ V mains. Find the current each draws.
  • 7 Explain why the instantaneous power taken by an inductive circuit is negative for part of each cycle. Where does the energy go?
  • 8 A series LCR circuit has $R=10\ \Omega$ and $Z=20\ \Omega$. Find the power factor and the phase angle.
1 $P=VI\cos\phi=(220)(5.0)(0.50)=550$ W.
2 $Z=50\ \Omega$; $\cos\phi=\dfrac{30}{50}=0.60$.
3 $Z=50\ \Omega$, $I=2.0$ A; $\cos\phi=0.80$, leading (capacitive); $P=I^2R=160$ W ($=VI\cos\phi=(100)(2.0)(0.80)$ ✓).
4 $X_L=157\ \Omega$, $I\approx1.40$ A; $P=0$ (power factor zero).
5 (a) $1$. (b) $Z=\sqrt2R$, so $\cos\phi=1/\sqrt2\approx0.71$.
6 Heater: $I=\dfrac{2000}{230}\approx8.7$ A. Motor: $I=\dfrac{2000}{(230)(0.80)}\approx10.9$ A.
7 $p=vi$ is negative whenever $v$ and $i$ have opposite signs, which happens for a fraction $|\phi|/\pi$ of each cycle when they are out of phase. During those intervals the inductor's magnetic field gives back energy it stored earlier, and that energy returns to the source.
8 $\cos\phi=\dfrac{10}{20}=0.50$; $|\phi|=60^\circ$.
II
Wattless current.
  • 1 An rms current of $10$ A lags the voltage by $30^\circ$. Find its active and wattless components.
  • 2 A coil draws $5.0$ A from a $200$ V AC supply and takes $600$ W. Find the power factor, the coil's resistance and its reactance.
  • 3 Why is the current through a pure inductor called a wattless current?
  • 4 Why is a choke, rather than a resistor, used to limit the current in an AC circuit such as an old fluorescent fitting?
  • 5 A factory takes $100$ kW at $400$ V. Find the line current at power factor $0.50$ and at $1.0$. By what factor is the loss in its supply cable reduced by the improvement?
  • 6 A lamp rated $50$ W, $100$ V is to be run from $200$ V, $50$ Hz using a pure inductor in series. Find the inductance required.
  • 7 A $60\ \Omega$ resistor and a capacitor of reactance $80\ \Omega$ are in series across $100$ V. Find the current, the average power and the wattless component of the current.
1 Active $10\cos30^\circ\approx8.66$ A; wattless $10\sin30^\circ=5.0$ A.
2 $\cos\phi=\dfrac{600}{(200)(5.0)}=0.60$; $R=\dfrac{P}{I^2}=\dfrac{600}{25}=24\ \Omega$; $Z=\dfrac{200}{5.0}=40\ \Omega$, so $X_L=\sqrt{40^2-24^2}=32\ \Omega$.
3 It is $90^\circ$ out of phase with the voltage, so $\cos\phi=0$ and the average power $VI\cos\phi$ is zero, however large the current.
4 A choke reduces the current through its reactance and (ideally) takes no average power, whereas a resistor would waste energy as heat.
5 $\cos\phi=0.50$: $I=\dfrac{10^5}{(400)(0.50)}=500$ A. $\cos\phi=1$: $I=250$ A. The cable loss $\propto I^2$ falls by a factor of $4$.
6 $I=\dfrac{50}{100}=0.50$ A; $V_L=\sqrt{200^2-100^2}\approx173$ V; $X_L\approx346\ \Omega$; $L=\dfrac{346}{100\pi}\approx1.10$ H.
7 $Z=100\ \Omega$, $I=1.0$ A; $P=I^2R=60$ W; $\sin\phi=\dfrac{80}{100}$, so the wattless component is $0.80$ A (leading).
III
Transformers.
  • 1 A transformer has $500$ primary turns and $2500$ secondary turns. The primary is connected to $230$ V AC. Find the secondary voltage. Is it step-up or step-down?
  • 2 A doorbell transformer gives $6.0$ V from the $230$ V mains. Its primary has $1150$ turns. How many turns has the secondary?
  • 3 An ideal step-down transformer has a turns ratio of $10:1$. The secondary current is $4.0$ A. Find the primary current.
  • 4 A transformer takes $1.0$ A at $230$ V and delivers $9.0$ A at $22$ V to a resistive load. Find its efficiency.
  • 5 Why does a transformer not work if its primary is connected to a battery?
  • 6 Why is the core of a transformer laminated? Why is the low-voltage winding made of thicker wire than the high-voltage winding?
  • 7 A step-up transformer increases the voltage. Does it violate the conservation of energy? Explain.
  • 8 An ideal transformer steps $11$ kV down to $230$ V and supplies $46$ kW to houses. Find the secondary current, the primary current and the turns ratio.
1 $V_s=230\times\dfrac{2500}{500}=1150$ V; step-up.
2 $N_s=1150\times\dfrac{6.0}{230}=30$ turns.
3 $I_p=I_s\dfrac{N_s}{N_p}=\dfrac{4.0}{10}=0.40$ A.
4 $\eta=\dfrac{(22)(9.0)}{(230)(1.0)}=\dfrac{198}{230}\approx86\%$.
5 A steady current produces a steady flux; with no change of flux, no emf is induced in the secondary.
6 Thin insulated laminations break up the paths of the currents induced in the iron, reducing the heating of the core. The low-voltage winding carries the larger current; thick wire has a small resistance, which keeps its $I^2R$ loss down.
7 No. The current is stepped down by the same factor, so the output power $V_sI_s$ is at most the input power $V_pI_p$.
8 $I_s=\dfrac{46\,000}{230}=200$ A; $I_p=\dfrac{46\,000}{11\,000}\approx4.2$ A; $\dfrac{N_p}{N_s}=\dfrac{11\,000}{230}\approx48$ (about $48:1$).
IV
Transmission and harder problems.
  • 1 A power station sends $1.0$ MW through lines of total resistance $5.0\ \Omega$. Find the line current and the power lost (a) at $20$ kV, (b) at $200$ kV.
  • 2 The transmission voltage of a line is increased from $33$ kV to $132$ kV, sending the same power. By what factor does the line loss change?
  • 3 A series circuit has $R=20\ \Omega$, $L=0.10$ H and $C=10\ \mu\text{F}$ across $100$ V (rms). Find the average power at $159$ Hz and at $50$ Hz.
  • 4 Show that the average power taken by a series LCR circuit is $P=\dfrac{V^2R}{Z^2}$.
  • 5 A $440$ V generator feeds a $1:25$ step-up transformer; at the town an $11$ kV-to-$220$ V transformer supplies the houses. Find the turns ratio of the second transformer and the voltage stepping overall.
  • 6 For $v=200\sin(100\pi t)$ V and $i=5.0\sin\!\left(100\pi t-\dfrac\pi3\right)$ A, find the average power and the power factor.
1 (a) $I=\dfrac{10^6}{2.0\times10^4}=50$ A; loss $(50)^2(5.0)$ $=12.5$ kW ($1.25\%$). (b) $I=5.0$ A; loss $125$ W ($0.0125\%$).
2 The voltage is $4$ times larger, so the loss is $4^2=16$ times smaller.
3 $159$ Hz is resonance: $P=\dfrac{V^2}{R}=500$ W. At $50$ Hz, $Z\approx288\ \Omega$, $I\approx0.348$ A, $P=I^2R\approx2.4$ W.
4 $P=VI\cos\phi$ with $I=\dfrac VZ$ and $\cos\phi=\dfrac RZ$: $P=V\cdot\dfrac VZ\cdot\dfrac RZ=\dfrac{V^2R}{Z^2}$.
5 $440\times25=11\,000$ V. Second transformer: $\dfrac{11\,000}{220}=50$, a $50:1$ step-down. Overall $440$ V $\to220$ V, a factor of $\tfrac12$, but the long line runs at $11$ kV.
6 The current lags by $\phi=60^\circ$: $\cos\phi=0.50$; $P=\tfrac12v_mi_m\cos\phi$ $=\tfrac12(200)(5.0)(0.50)$ $=250$ W.
🎯 Exam corner — AC power and transformers BoardJEE MainJEE AdvancedNEET

E1. Board · 3 marks Show that the average power taken by an AC circuit is $VI\cos\phi$, where $\phi$ is the phase difference between the current and the voltage. Define power factor and state when it is (a) zero, (b) one.

Instantaneous power $v=v_m\sin\omega t$, $i=i_m\sin(\omega t+\phi)$: $p=vi=\dfrac{v_mi_m}{2}\left[\cos\phi-\cos(2\omega t+\phi)\right]$.
Average $\overline{\cos(2\omega t+\phi)}=0$ over a cycle, so $P=\dfrac{v_mi_m}{2}\cos\phi$ $=\dfrac{v_m}{\sqrt2}\dfrac{i_m}{\sqrt2}\cos\phi$ $=VI\cos\phi$.
Power factor $\cos\phi=\dfrac{P}{VI}$ ($=R/Z$ for a series LCR circuit). (a) Zero for a pure inductor or capacitor ($\phi=\pm\pi/2$). (b) One for a pure resistor or a series LCR circuit at resonance. Exam tip: quote the identity $2\sin A\sin B=\cos(A-B)-\cos(A+B)$ — it is the key step.

E2. Board · 2 marks State the principle of a transformer. An ideal transformer has $100$ turns in its primary and $2000$ in its secondary; the primary is connected to a $12$ V AC supply and the secondary to a $480\ \Omega$ resistor. Find the secondary voltage and the primary current.

Principle Mutual induction: an alternating current in the primary produces an alternating flux in the common core, which induces an emf in the secondary.
Numbers $V_s=12\times\dfrac{2000}{100}=240$ V; $I_s=\dfrac{240}{480}=0.50$ A; $I_p=I_s\dfrac{N_s}{N_p}=0.50\times20=10$ A. Exam tip: check with power — $12\times10=240\times0.50=120$ W ✓.

E3. Board · 1 mark Assertion (A): Electric power is transmitted over long distances at very high voltages. Reason (R): For a given power, a higher voltage means a smaller current and so a smaller $I^2R$ loss in the lines. (A) Both A and R are true and R is the correct explanation of A. (B) Both are true but R is not the correct explanation of A. (C) A is true, R is false. (D) A is false, R is true.

Concept $I=P/V$ and $P_\text{loss}=I^2R_\text{line}=P^2R_\text{line}/V^2$. R is true and explains A.
Answer (A). Exam tip: it is the current, not the voltage, that heats the wires.

E4. NEET For $v=100\sin\omega t$ V and $i=2.0\sin\!\left(\omega t+\dfrac\pi3\right)$ A, the average power is (A) $50$ W (B) $100$ W (C) $86.6$ W (D) $200$ W.

Formula $P=\tfrac12v_mi_m\cos\phi$ $=\tfrac12(100)(2.0)\cos60^\circ$ $=50$ W.
Answer (A). Exam tip: (B) forgets the $\cos\phi$; (C) uses $\sin\phi$. With peak values, remember the $\tfrac12$.

E5. JEE Main An rms current of $5.0$ A flows in a circuit, lagging the voltage by $60^\circ$. The wattless component of the current is (A) $2.5$ A (B) $4.33$ A (C) $5.0$ A (D) zero.

Concept Wattless component $=I\sin\phi=5.0\sin60^\circ\approx4.33$ A (the active component is $I\cos\phi=2.5$ A).
Answer (B). Exam tip: wattless goes with $\sin\phi$, power with $\cos\phi$.

E6. JEE Advanced (Integer answer.) A series LCR circuit with $R=10\ \Omega$ takes $1000$ W from a $100$ V (rms) variable-frequency source at resonance. At another frequency it takes $500$ W. Find $|X_L-X_C|$ at that frequency, in ohms.

Power $P=\dfrac{V^2R}{Z^2}$. At resonance $Z=R$: $\dfrac{100^2}{10}=1000$ W ✓.
Impedance $500=\dfrac{(100)^2(10)}{Z^2}\Rightarrow Z^2=200\ \Omega^2$, so $(X_L-X_C)^2=Z^2-R^2=100$.
Answer $|X_L-X_C|=10\ \Omega$. Answer: 10. Exam tip: half the resonant power means a half-power point, where $|X_L-X_C|=R$ — you could have written $10$ at once.
🔬 Research–Teaching NexusResearch-tutored · optional, about 40 minutes

Research question. On a rural distribution line, which saves more energy: raising the line voltage, or raising the power factor of the customers' loads?

Why it matters. A noticeable fraction of all electricity generated never reaches a customer — it heats lines and transformers on the way. Grid operators in India, Brazil, South Africa and across Europe publish these "transmission and distribution losses" and spend large sums reducing them: upgrading lines to higher voltage, installing capacitor banks, and charging industrial users for poor power factor. The physics of Results 7.8 and 7.10 decides which option is worth the money.

What to do.

  1. Use this illustrative feeder: it delivers $2.0$ MW of real power to villages through lines of total resistance $1.5\ \Omega$; the loads have power factor $0.80$; the line runs at $11$ kV.
  2. Find the line current $I=P/(V\cos\phi)$ and the line loss $I^2R$, and express the loss as a percentage of $2.0$ MW.
  3. Repeat with the power factor raised to $1.0$ (capacitor banks), then with the voltage raised to $33$ kV (power factor still $0.80$), then with both.
  4. Tabulate the four cases. Over a year ($8760$ hours, assuming this average load), how many kWh does each change save?

Tools: Calculator or spreadsheet; Interactive 1 and 2 to explore the trends.

Hand in: Your table, the annual savings, and a short recommendation to the grid operator. Look up the published loss figure for your own country's grid and compare.

Going further. Raising the voltage needs new insulators, towers and transformers; capacitor banks are cheap but must be switched as the load changes. Which costs would you need to know to make a real decision?

Instructor note: $11$ kV, $\cos\phi=0.80$: $I\approx227$ A, loss $\approx77.5$ kW ($3.9\%$). $11$ kV, $\cos\phi=1$: $I\approx182$ A, loss $\approx49.6$ kW ($2.5\%$). $33$ kV, $0.80$: $I\approx75.8$ A, loss $\approx8.6$ kW ($0.43\%$). $33$ kV, $1$: $I\approx60.6$ A, loss $\approx5.5$ kW ($0.28\%$). Power-factor correction alone saves about $28$ kW ($\approx2.4\times10^5$ kWh a year); tripling the voltage saves about $69$ kW ($\approx6.0\times10^5$ kWh a year) — the $1/V^2$ law wins, but the capacitor option is far cheaper.

🧪 Self-check quiz

0/5 correct

Q1. The power factor of a circuit containing only a pure inductor is

Q2. A circuit draws $2.0$ A from a $220$ V supply at a power factor of $0.50$. The average power is

Q3. An ideal transformer has $100$ primary turns and $2000$ secondary turns. With $12$ V AC on the primary, the secondary voltage is

Q4. Power is transmitted at high voltage mainly because

Q5. The power factor of a series circuit with $R=8\ \Omega$ and $X_L=6\ \Omega$ is