7.3 Power in AC Circuits and the Transformer
Only the resistance in an AC circuit takes energy on average: the power is $P=VI\cos\phi$, and the part of the current out of step with the voltage is wattless. Transformers change AC voltages with almost no loss, which is why power travels at high voltage.
Large factories in many countries pay a penalty on their electricity bill if their "power factor" is too low — even when they use exactly the same number of kilowatt-hours as a neighbour. Why should a utility care how the energy is used? Because an electric motor full of coils draws a current that is partly out of step with the voltage. That part of the current delivers no energy on average, yet it flows through every cable, transformer and generator between the power station and the factory and heats them all. The cure — banks of capacitors — follows directly from the phasors of Section 7.2.
In this section we find the average power in an AC circuit, $P=VI\cos\phi$, define the power factor $\cos\phi$ and the wattless current, and then turn to the device that makes AC the world's choice for power networks: the transformer. We see how a pair of coils on an iron core steps a voltage up or down, what limits its efficiency, and why sending power at high voltage cuts the energy wasted in the transmission lines.
Power in an AC Circuit
Let the source voltage be $v=v_m\sin\omega t$ and the current $i=i_m\sin(\omega t+\phi)$. The instantaneous power delivered by the source is $$p=vi=v_mi_m\sin\omega t\,\sin(\omega t+\phi).$$ Using $2\sin A\sin B=\cos(A-B)-\cos(A+B)$, $$p=\frac{v_mi_m}{2}\left[\cos\phi-\cos(2\omega t+\phi)\right].$$ The second term oscillates at twice the supply frequency and averages to zero over a cycle. The first term is constant.
The average power taken by a circuit in which the current differs in phase from the voltage by $\phi$ is $$P=\frac{v_mi_m}{2}\cos\phi=VI\cos\phi,$$ with $V$, $I$ rms values. For a series LCR circuit $\cos\phi=\dfrac RZ$, so $$P=I^2Z\cdot\frac RZ=I^2R:$$ all the average power is dissipated in the resistance.
The four important cases:
- Pure resistor: $\phi=0$, $\cos\phi=1$, $P=VI$ — the largest possible.
- Pure inductor or capacitor: $\phi=\pm\pi/2$, $\cos\phi=0$, $P=0$ although a current flows (Section 7.1).
- Series LCR circuit: $\cos\phi=R/Z$, $P=I^2R$.
- At resonance: $Z=R$, $\cos\phi=1$, $P=V^2/R$ — the most power the circuit can take from the source.
The instantaneous power $p$ is negative for part of every cycle whenever $\phi\ne0$: during those intervals the coil or capacitor hands stored energy back to the source.
Wattless Current and the Power Factor
Draw the current phasor $\mathbf I$ at angle $\phi$ to the voltage phasor $\mathbf V$ and split it into two perpendicular components. The part $I\cos\phi$ along $\mathbf V$ is in phase with the voltage and carries all the power, $V(I\cos\phi)$. The part $I\sin\phi$ is $90^\circ$ out of phase with the voltage — like the current in a pure inductor or capacitor — and carries none.
Wattless current is not harmless. It flows through the supply cables and the generator windings and heats them ($I^2R$ depends on the whole current), and for a given power a small $\cos\phi$ means a large current $I=P/(V\cos\phi)$. Electric motors, welding sets and old fluorescent fittings are inductive and can have power factors of $0.6$–$0.8$. Utilities therefore ask large customers to keep $\cos\phi$ close to $1$, usually by connecting capacitors across the supply (see the 🚀 box).
The Transformer
A transformer is two coils wound on the same core of soft iron: the primary, with $N_p$ turns, connected to the AC supply, and the secondary, with $N_s$ turns, connected to the load. The alternating current in the primary sets up an alternating magnetic flux in the core, and the iron guides almost all of that flux through the secondary as well. By mutual induction (Chapter 6) the changing flux induces an emf in every turn of both coils.
Suppose (i) all the flux $\Phi$ through each turn of the primary also passes through each turn of the secondary (no flux leakage), and (ii) the coils have negligible resistance. Each turn then has the same induced emf $-d\Phi/dt$, so $$\varepsilon_p=-N_p\frac{d\Phi}{dt},\qquad \varepsilon_s=-N_s\frac{d\Phi}{dt}.$$ With no resistance the primary emf balances the applied voltage, $v_p=-\varepsilon_p$, and on open circuit the secondary voltage is $v_s=-\varepsilon_s$. Dividing, $\dfrac{v_s}{v_p}=\dfrac{N_s}{N_p}$ — at every instant, and therefore for rms values too. If, in addition, (iii) no energy is lost, the power drawn from the supply equals the power delivered to the load: $V_pI_p=V_sI_s$.
For an ideal transformer (no flux leakage, no winding resistance, no energy losses in the core), $$\frac{V_s}{V_p}=\frac{N_s}{N_p},\qquad \frac{I_s}{I_p}=\frac{N_p}{N_s}.$$ Stepping the voltage up by some factor steps the current down by the same factor, so $V_pI_p=V_sI_s$. A transformer does not work with a steady (d.c.) supply: a steady current gives a steady flux and induces no emf.
A transformer is not a source of free energy: a step-up transformer raises the voltage only by lowering the current. The secondary current is set by the load ($I_s=V_s/Z_\text{load}$), and the primary then draws just enough current to supply that power.
Energy losses in real transformers. Large transformers reach efficiencies above $95\%$, but some energy is always lost:
- Flux leakage — some flux of the primary misses the secondary. Reduced by winding the two coils one over the other.
- Resistance of the windings — $I^2R$ heating ("copper loss"). Reduced by using thick wire, especially for the low-voltage, high-current coil.
- Currents induced in the iron core (eddy currents), which heat it. Reduced by building the core from thin insulated sheets — a laminated core.
- Hysteresis — energy used in magnetising the core back and forth every cycle (Chapter 5). Reduced by using soft iron, which is easy to magnetise and demagnetise.
The efficiency of a transformer is $\eta=\dfrac{\text{output power}}{\text{input power}}=\dfrac{V_sI_s}{V_pI_p}$ (for loads with power factor close to 1).
Transmitting Power at High Voltage
A power station must send a power $P$ to a distant town along lines of total resistance $R_\text{line}$. The current in the lines is $I=P/V$, where $V$ is the transmission voltage (taking the power factor as $1$), and the power lost as heat in the lines is $I^2R_\text{line}$.
Sending a power $P$ at voltage $V$ through lines of resistance $R_\text{line}$ wastes $$P_\text{loss}=I^2R_\text{line}=\frac{P^2R_\text{line}}{V^2}.$$ For a given power and line, the loss is inversely proportional to the square of the transmission voltage: raising $V$ ten times cuts the loss a hundred times.
This is the reason for alternating current. Generators produce a few kilovolts to a few tens of kilovolts; step-up transformers at the power station raise this to $220$ kV, $400$ kV or $765$ kV for long-distance lines; a chain of step-down transformers then lowers it to $33$ kV, $11$ kV and finally $230$ V for homes. A d.c. system cannot change its voltage so simply, which is why the AC grid won the "war of the currents" at the end of the nineteenth century.
1. Writing $P=VI$ for every AC circuit. $P=VI\cos\phi$; $VI$ is only the apparent power.
2. Using $P=I^2Z$. Only the resistance dissipates energy: $P=I^2R$.
3. Thinking a step-up transformer gives more power. It raises the voltage and lowers the current; at best $V_sI_s=V_pI_p$.
4. Inverting the current ratio. $\dfrac{I_s}{I_p}=\dfrac{N_p}{N_s}$ — the high-voltage coil carries the small current.
5. Using $V^2/R_\text{line}$ for the line loss with the transmission voltage. The voltage across the line itself is $IR_\text{line}$, not $V$. Use $I^2R_\text{line}$ with $I=P/V$.
Not required by the CBSE syllabus. Power in AC circuits and wattless current are listed by JEE Main and NEET, and JEE Advanced lists LCR circuits with a.c. sources; the power triangle and power-factor correction are applications that no syllabus names.
Multiply the sides of the current triangle ($I\cos\phi$, $I\sin\phi$, $I$) by $V$ and you get the power triangle: the real power $P=VI\cos\phi$ (watts), the reactive power $VI\sin\phi$ (often quoted in "volt-ampere reactive", var) and the apparent power $VI$ (VA), with $(VI)^2=P^2+(VI\sin\phi)^2$.
Correcting the power factor. An inductive load's wattless current lags the voltage by $90^\circ$; a capacitor connected across the supply draws a current $V\omega C$ that leads the voltage by $90^\circ$. If the two are equal they cancel in the supply lines, which then carry only the active current. For the motor of Example 3 ($230$ V, $50$ Hz, wattless current $6.0$ A) we need $V\omega C=6.0$ A: $$C=\frac{6.0}{(230)(2\pi\cdot50)}\approx8.3\times10^{-5}\ \text{F},$$ that is, about $83\ \mu\text{F}$. The line current then falls from $10$ A to $8.0$ A and the power factor seen by the supply rises to $1$, while the motor itself is unchanged. Industrial plants install switched capacitor banks to do this as their load varies.
Exercises
- 1 A circuit draws $5.0$ A from a $220$ V supply, with the current lagging the voltage by $60^\circ$. Find the average power.
- 2 Find the power factor of a series circuit with $R=30\ \Omega$ and $X_L=40\ \Omega$.
- 3 A $40\ \Omega$ resistor and a capacitor of reactance $30\ \Omega$ are in series across $100$ V. Find the current, the power factor and the average power. Is the power factor leading or lagging?
- 4 A $0.50$ H coil of negligible resistance is connected to $220$ V, $50$ Hz. Find the current and the average power.
- 5 What is the power factor of a series LCR circuit (a) at resonance, (b) at a half-power frequency?
- 6 A $2.0$ kW heater and a $2.0$ kW motor (power factor $0.80$) are each connected to the $230$ V mains. Find the current each draws.
- 7 Explain why the instantaneous power taken by an inductive circuit is negative for part of each cycle. Where does the energy go?
- 8 A series LCR circuit has $R=10\ \Omega$ and $Z=20\ \Omega$. Find the power factor and the phase angle.
- 1 An rms current of $10$ A lags the voltage by $30^\circ$. Find its active and wattless components.
- 2 A coil draws $5.0$ A from a $200$ V AC supply and takes $600$ W. Find the power factor, the coil's resistance and its reactance.
- 3 Why is the current through a pure inductor called a wattless current?
- 4 Why is a choke, rather than a resistor, used to limit the current in an AC circuit such as an old fluorescent fitting?
- 5 A factory takes $100$ kW at $400$ V. Find the line current at power factor $0.50$ and at $1.0$. By what factor is the loss in its supply cable reduced by the improvement?
- 6 A lamp rated $50$ W, $100$ V is to be run from $200$ V, $50$ Hz using a pure inductor in series. Find the inductance required.
- 7 A $60\ \Omega$ resistor and a capacitor of reactance $80\ \Omega$ are in series across $100$ V. Find the current, the average power and the wattless component of the current.
- 1 A transformer has $500$ primary turns and $2500$ secondary turns. The primary is connected to $230$ V AC. Find the secondary voltage. Is it step-up or step-down?
- 2 A doorbell transformer gives $6.0$ V from the $230$ V mains. Its primary has $1150$ turns. How many turns has the secondary?
- 3 An ideal step-down transformer has a turns ratio of $10:1$. The secondary current is $4.0$ A. Find the primary current.
- 4 A transformer takes $1.0$ A at $230$ V and delivers $9.0$ A at $22$ V to a resistive load. Find its efficiency.
- 5 Why does a transformer not work if its primary is connected to a battery?
- 6 Why is the core of a transformer laminated? Why is the low-voltage winding made of thicker wire than the high-voltage winding?
- 7 A step-up transformer increases the voltage. Does it violate the conservation of energy? Explain.
- 8 An ideal transformer steps $11$ kV down to $230$ V and supplies $46$ kW to houses. Find the secondary current, the primary current and the turns ratio.
- 1 A power station sends $1.0$ MW through lines of total resistance $5.0\ \Omega$. Find the line current and the power lost (a) at $20$ kV, (b) at $200$ kV.
- 2 The transmission voltage of a line is increased from $33$ kV to $132$ kV, sending the same power. By what factor does the line loss change?
- 3 A series circuit has $R=20\ \Omega$, $L=0.10$ H and $C=10\ \mu\text{F}$ across $100$ V (rms). Find the average power at $159$ Hz and at $50$ Hz.
- 4 Show that the average power taken by a series LCR circuit is $P=\dfrac{V^2R}{Z^2}$.
- 5 A $440$ V generator feeds a $1:25$ step-up transformer; at the town an $11$ kV-to-$220$ V transformer supplies the houses. Find the turns ratio of the second transformer and the voltage stepping overall.
- 6 For $v=200\sin(100\pi t)$ V and $i=5.0\sin\!\left(100\pi t-\dfrac\pi3\right)$ A, find the average power and the power factor.
E1. Board · 3 marks Show that the average power taken by an AC circuit is $VI\cos\phi$, where $\phi$ is the phase difference between the current and the voltage. Define power factor and state when it is (a) zero, (b) one.
E2. Board · 2 marks State the principle of a transformer. An ideal transformer has $100$ turns in its primary and $2000$ in its secondary; the primary is connected to a $12$ V AC supply and the secondary to a $480\ \Omega$ resistor. Find the secondary voltage and the primary current.
E3. Board · 1 mark Assertion (A): Electric power is transmitted over long distances at very high voltages. Reason (R): For a given power, a higher voltage means a smaller current and so a smaller $I^2R$ loss in the lines. (A) Both A and R are true and R is the correct explanation of A. (B) Both are true but R is not the correct explanation of A. (C) A is true, R is false. (D) A is false, R is true.
E4. NEET For $v=100\sin\omega t$ V and $i=2.0\sin\!\left(\omega t+\dfrac\pi3\right)$ A, the average power is (A) $50$ W (B) $100$ W (C) $86.6$ W (D) $200$ W.
E5. JEE Main An rms current of $5.0$ A flows in a circuit, lagging the voltage by $60^\circ$. The wattless component of the current is (A) $2.5$ A (B) $4.33$ A (C) $5.0$ A (D) zero.
E6. JEE Advanced (Integer answer.) A series LCR circuit with $R=10\ \Omega$ takes $1000$ W from a $100$ V (rms) variable-frequency source at resonance. At another frequency it takes $500$ W. Find $|X_L-X_C|$ at that frequency, in ohms.
Research question. On a rural distribution line, which saves more energy: raising the line voltage, or raising the power factor of the customers' loads?
Why it matters. A noticeable fraction of all electricity generated never reaches a customer — it heats lines and transformers on the way. Grid operators in India, Brazil, South Africa and across Europe publish these "transmission and distribution losses" and spend large sums reducing them: upgrading lines to higher voltage, installing capacitor banks, and charging industrial users for poor power factor. The physics of Results 7.8 and 7.10 decides which option is worth the money.
What to do.
- Use this illustrative feeder: it delivers $2.0$ MW of real power to villages through lines of total resistance $1.5\ \Omega$; the loads have power factor $0.80$; the line runs at $11$ kV.
- Find the line current $I=P/(V\cos\phi)$ and the line loss $I^2R$, and express the loss as a percentage of $2.0$ MW.
- Repeat with the power factor raised to $1.0$ (capacitor banks), then with the voltage raised to $33$ kV (power factor still $0.80$), then with both.
- Tabulate the four cases. Over a year ($8760$ hours, assuming this average load), how many kWh does each change save?
Tools: Calculator or spreadsheet; Interactive 1 and 2 to explore the trends.
Hand in: Your table, the annual savings, and a short recommendation to the grid operator. Look up the published loss figure for your own country's grid and compare.
Going further. Raising the voltage needs new insulators, towers and transformers; capacitor banks are cheap but must be switched as the load changes. Which costs would you need to know to make a real decision?
🧪 Self-check quiz
Q1. The power factor of a circuit containing only a pure inductor is
Q2. A circuit draws $2.0$ A from a $220$ V supply at a power factor of $0.50$. The average power is
Q3. An ideal transformer has $100$ primary turns and $2000$ secondary turns. With $12$ V AC on the primary, the secondary voltage is
Q4. Power is transmitted at high voltage mainly because
Q5. The power factor of a series circuit with $R=8\ \Omega$ and $X_L=6\ \Omega$ is