1.3 Errors in Measurement
No measurement is exact. Least count, systematic and random errors, the mean absolute error, and the rules that carry errors through sums, products and powers: $\dfrac{\Delta Z}{Z}=p\dfrac{\Delta A}{A}+q\dfrac{\Delta B}{B}+r\dfrac{\Delta C}{C}$.
Time one swing of a pendulum with a stopwatch five times and you will almost never get the same number twice: $2.03\ \text{s}$, $1.98\ \text{s}$, $2.01\ \text{s}$… Measure the thickness of a coin with a ruler and you can only say "a little under $2\ \text{mm}$"; a screw gauge says $1.85\ \text{mm}$. Every measured number carries an uncertainty, set by the instrument, the method and the person using it. A result such as $g=9.8\ \text{m/s}^2$ means little until we also say how far it might be wrong: $9.8\pm0.1$ and $9.8\pm2$ are very different claims. Engineers who machine engine parts, doctors reading a blood-pressure gauge and the scientists who fixed the values of the SI constants all live by this rule.
This section teaches you to measure the doubt. First, the smallest step an instrument can show — its least count — and the difference between accuracy and precision. Then the two families of error, systematic and random, and how repeated readings give a best value and a mean absolute error. Finally the rules that tell you how errors in measured quantities combine when you add, subtract, multiply, divide or raise them to powers — the single most frequently tested idea of this chapter in JEE Main. The significant-figure rules of Section 1.1 are a quick form of these rules; here you will see where they come from.
Least count, accuracy and precision
Every instrument has a smallest division it can resolve. A metre scale is marked in millimetres, so a length can be read to the nearest $1\ \text{mm}$ and no better; any reading is uncertain by about one such division. Better instruments push this limit down by clever mechanical magnification: the Vernier callipers slide a second small scale along the main one, and the screw gauge turns a fine screw whose head is divided into many parts.
The least count (LC) of an instrument is the smallest value of a quantity that it can measure — the change in the quantity that moves the reading by one smallest division. Any single reading has an uncertainty (the least count error) of about one least count.
Accuracy describes how close a measurement is to the true value. Precision describes how finely a quantity is resolved and how closely repeated measurements agree with one another. A measurement can be precise without being accurate (all readings agree, but all are off by the same amount) and vice versa.
Vernier callipers. If $n$ divisions of the Vernier scale (VSD) have the same length as $(n-1)$ divisions of the main scale (MSD), then $1\ \text{VSD}=\tfrac{n-1}{n}\ \text{MSD}$ and
$$\text{LC}=1\ \text{MSD}-1\ \text{VSD}=\frac{1\ \text{MSD}}{n}.$$To read it: take the main-scale reading (MSR) just before the Vernier zero, find the Vernier division $k$ that lines up exactly with a main-scale mark, and add: reading $=\text{MSR}+k\times\text{LC}$. With $1\ \text{MSD}=1\ \text{mm}$ and $n=10$, $\text{LC}=0.1\ \text{mm}=0.01\ \text{cm}$.
Screw gauge. One full turn moves the spindle forward by the pitch $p$; the head carries $N$ circular-scale divisions, so
$$\text{LC}=\frac{\text{pitch}}{N}.$$A gauge with pitch $0.5\ \text{mm}$ and $50$ divisions has $\text{LC}=0.01\ \text{mm}$. Reading $=$ main (linear) scale reading $+$ (circular-scale division on the reference line) $\times$ LC.
Zero error. If an instrument does not read zero when the jaws are closed, every reading is shifted by the same amount, the zero error $e_0$ (positive if the instrument reads too much, negative if it reads too little). It is removed by subtracting it with its sign:
$$\text{corrected reading}=\text{observed reading}-e_0 .$$Vernier callipers have a zero error of $-0.03\ \text{cm}$ (with the jaws closed, the Vernier zero lies to the left of the main-scale zero). A rod gives an observed reading of $3.45\ \text{cm}$. Its corrected length is
Systematic and random errors; absolute, relative and percentage errors
The error in a measurement is the difference between the measured value and the true value. We never know the true value exactly, but we can understand where errors come from, remove the ones we can, and estimate the size of the rest.
Systematic errors push every reading in the same direction (always too large or always too small) by roughly the same amount. Their sources are
- instrumental — a zero error, a badly calibrated scale, a stopwatch that runs slow;
- imperfect technique or method — ignoring air resistance, heat loss to the surroundings, or measuring a body temperature with the thermometer under the arm;
- personal — for example, always reading a scale from slightly above (parallax), or always stopping a watch a little late.
They are reduced by better instruments and methods and by applying corrections (such as subtracting the zero error). Repeating the measurement does not reduce them.
Random errors vary irregularly in size and sign from one reading to the next — from small, unpredictable changes in the conditions (vibrations, temperature, the observer's reaction time). They are equally likely to be positive or negative, so they largely cancel when many readings are averaged.
Suppose a quantity is measured $n$ times, giving $a_1,a_2,\ldots,a_n$. With no systematic error, the best estimate of the true value is the arithmetic mean. The scatter of the readings about the mean tells us how large the random errors are.
Mean value (best estimate): $\displaystyle\bar a=\frac{a_1+a_2+\dots+a_n}{n}=\frac1n\sum_{i=1}^{n}a_i$.
Absolute error of the $i$-th reading: $\Delta a_i=|a_i-\bar a|$, with the same unit as $a$.
Mean absolute error: $\displaystyle\Delta\bar a=\frac1n\sum_{i=1}^{n}|\Delta a_i|$. The result is reported as $a=\bar a\pm\Delta\bar a$: the true value very probably lies between $\bar a-\Delta\bar a$ and $\bar a+\Delta\bar a$.
Relative (fractional) error: $\dfrac{\Delta\bar a}{\bar a}$ — a pure number. Percentage error: $\delta a=\dfrac{\Delta\bar a}{\bar a}\times100\%$.
Two practical rules. (i) The mean absolute error can never honestly be smaller than the least count: if your readings agree so well that $\Delta\bar a$ comes out below the LC, quote the LC as the error. For a single reading, the error is the least count itself. (ii) An error is itself only an estimate, so round it to one significant figure (two if it begins with 1, when that helps), then round the value to the same decimal place: $9.672\pm0.106$ becomes $9.7\pm0.1$.
The relative error is what tells you how good a measurement is. An error of $1\ \text{mm}$ is excellent on the length of a corridor ($10\ \text{m}$: $0.01\%$) and useless on the diameter of a wire ($0.5\ \text{mm}$: $200\%$).
In Interactive 1 keep the scatter at $0.020\ \text{cm}$ and set readings to $20$. Now switch the error type to "random + zero error $+0.04$ cm". What happens to the mean $\bar a$ and to the mean absolute error $\Delta\bar a$?
Three readings of a length with a metre scale (least count $0.1\ \text{cm}$) all come out as $25.4\ \text{cm}$. The result should be written as
Combination of errors
Most physical quantities are not measured directly but calculated: a density from a mass and a volume, $g$ from a length and a period, a resistance from a voltage and a current. If each input has an error, how large is the error in the answer? JEE Main uses the maximum (worst-case) error: we assume all the individual errors push the result the same way, so they add. Throughout, $\Delta A$, $\Delta B$, … are small compared with $A$, $B$, …
If $A\pm\Delta A$ and $B\pm\Delta B$ are measured and $Z=A+B$ or $Z=A-B$, the maximum absolute error in $Z$ is
$$\Delta Z=\Delta A+\Delta B .$$Absolute errors add — for a difference as well as for a sum.
Why. For a sum, $Z\pm\Delta Z=(A\pm\Delta A)+(B\pm\Delta B)$; the largest possible deviation is when both errors have the same sign, $\pm(\Delta A+\Delta B)$. For a difference, the extreme values of $A-B$ are $(A+\Delta A)-(B-\Delta B)$ and $(A-\Delta A)-(B+\Delta B)$, i.e. $(A-B)\pm(\Delta A+\Delta B)$. The errors do not cancel just because the quantities are subtracted.
The consequence is important: the difference of two nearly equal quantities has a small value but the full sum of the absolute errors, so its percentage error can be very large (Example 3). Good experiments avoid relying on small differences when they can.
For products and quotients we need one small piece of algebra, the binomial approximation: for a small number $x$ (say $|x|\lt0.05$) and any power $n$,
$$(1+x)^n\approx1+nx .$$For example, $(1.02)^3=1.0612\approx1.06$ and $\sqrt{1.04}=1.0198\approx1.02$. The neglected terms contain $x^2$, which is tiny when $x$ is a few per cent.
If $Z=AB$ or $Z=\dfrac{A}{B}$, the maximum relative error in $Z$ is
$$\frac{\Delta Z}{Z}=\frac{\Delta A}{A}+\frac{\Delta B}{B} .$$Relative (or percentage) errors add — for a quotient as well as for a product. Valid when the relative errors are small (a few per cent), so that their products can be neglected.
Why. For a product,
$$Z\pm\Delta Z=(A\pm\Delta A)(B\pm\Delta B)$$ $$=AB\pm B\,\Delta A\pm A\,\Delta B\pm\Delta A\,\Delta B .$$Divide by $Z=AB$:
$$1\pm\frac{\Delta Z}{Z}=1\pm\frac{\Delta A}{A}\pm\frac{\Delta B}{B}\pm\frac{\Delta A}{A}\cdot\frac{\Delta B}{B}.$$The last term is a product of two small numbers (e.g. $0.02\times0.03=0.0006$) and is dropped; the worst case gives the rule. For a quotient, using the binomial approximation with $n=-1$,
$$\frac{A\pm\Delta A}{B\pm\Delta B}=\frac AB\left(1\pm\frac{\Delta A}{A}\right)\left(1\pm\frac{\Delta B}{B}\right)^{-1}$$ $$\approx\frac AB\left(1\pm\frac{\Delta A}{A}\right)\left(1\mp\frac{\Delta B}{B}\right),$$and the worst case again adds the two relative errors.
If $Z=k\,\dfrac{A^pB^q}{C^r}$, where $k$ is an exact constant and $p,q,r$ are positive numbers (whole or fractional), then
$$\frac{\Delta Z}{Z}=p\,\frac{\Delta A}{A}+q\,\frac{\Delta B}{B}+r\,\frac{\Delta C}{C}.$$Each relative error is multiplied by the magnitude of its power and all the terms are added, whether the quantity is in the numerator or the denominator. Exact constants ($2$, $\pi$, a counted number of oscillations) contribute no error. Valid for small relative errors.
Why. $(A\pm\Delta A)^p=A^p\left(1\pm\dfrac{\Delta A}{A}\right)^p\approx A^p\left(1\pm p\dfrac{\Delta A}{A}\right)$ by the binomial approximation, and the same for $B^q$ and $C^{-r}$; then Rule 1.10 adds the relative errors. A square root halves the relative error ($p=\tfrac12$); a cube triples it. So the quantity with the highest power usually dominates the error, and it is the one to measure most carefully.
- Write the formula in the form $Z=k\,A^pB^qC^{-r}\cdots$. Pull out exact constants; they carry no error.
- Check the structure. If the formula contains a sum or difference of measured quantities (such as $l_2-l_1$), first find that combination's absolute error with Rule 1.9 and treat it as one quantity. If the same quantity appears in more than one place in a non-power way (such as $\tfrac{R_1R_2}{R_1+R_2}$), rewrite the formula first (Example 6).
- Find each relative error $\dfrac{\Delta A}{A}$ (from the LC or the mean absolute error), multiply by the magnitude of its power, and add — never subtract.
- Convert back: $\Delta Z=Z\times\dfrac{\Delta Z}{Z}$; round $\Delta Z$ to one significant figure and $Z$ to the same decimal place.
Calculus shortcut (after Section 2.1): take logarithms, $\ln Z=\ln k+p\ln A+q\ln B-r\ln C$, differentiate, $\dfrac{dZ}{Z}=p\dfrac{dA}{A}+q\dfrac{dB}{B}-r\dfrac{dC}{C}$, and for the maximum error replace every minus sign by a plus.
Choose the formula $\rho=6m/(\pi d^3)$ and set both percentage errors — in the mass $m$ and in the diameter $d$ — to $1.00\%$. What total percentage error in $\rho$ will the widget show?
$Z=\dfrac{A^2}{B^3}$, where $A$ is measured with a $1\%$ error and $B$ with a $2\%$ error. The maximum percentage error in $Z$ is
Reciprocals, repeated quantities and reporting the result
Rule 1.11 assumes each measured quantity appears once, as a power. Formulas such as the parallel-resistor or lens formula break this: in $R=\dfrac{R_1R_2}{R_1+R_2}$ the resistance $R_1$ appears both on top and underneath. Treating the numerator and denominator as independent would count the error in $R_1$ twice, although an increase in $R_1$ raises both and the effects partly cancel. Instead, work with the reciprocal form. Since $\dfrac{1}{x\pm\Delta x}=\dfrac1x\left(1\pm\dfrac{\Delta x}{x}\right)^{-1}\approx\dfrac1x\mp\dfrac{\Delta x}{x^2}$, the absolute error of $\dfrac1x$ is $\dfrac{\Delta x}{x^2}$. Applying Rule 1.9 to $\dfrac1R=\dfrac1{R_1}+\dfrac1{R_2}$ gives
$$\frac{\Delta R}{R^2}=\frac{\Delta R_1}{R_1^2}+\frac{\Delta R_2}{R_2^2}.$$The same pattern holds for the lens formula written in magnitudes, $\dfrac1f=\dfrac1u+\dfrac1v$: $\dfrac{\Delta f}{f^2}=\dfrac{\Delta u}{u^2}+\dfrac{\Delta v}{v^2}$. Resistors in series are a plain sum: $\Delta R_s=\Delta R_1+\Delta R_2$.
Reporting a result. Write the best value, the error and the unit together, with the error rounded to one significant figure and the value rounded to the same decimal place: $g=(9.7\pm0.1)\ \text{m/s}^2$, $Y=(2.00\pm0.09)\times10^{11}\ \text{Pa}$, never $g=9.6722\pm0.1066\ \text{m/s}^2$. This is the deeper reason behind the significant-figure rules: the digits you keep are the ones the error allows.
1. Percentage errors for a difference. For $Z=A-B$ the absolute errors add; the percentage error of $Z$ is $\dfrac{\Delta A+\Delta B}{A-B}$, which can be huge (Example 3). Adding the percentage errors of $A$ and $B$ is wrong.
2. Subtracting for the denominator. In $g=\dfrac{4\pi^2l}{T^2}$ the error in $T$ is added: $\dfrac{\Delta g}{g}=\dfrac{\Delta l}{l}+2\dfrac{\Delta T}{T}$. Errors never cancel in the worst case.
3. Forgetting the power — or giving constants an error. Squares double, cubes triple, square roots halve. $\pi$, $\tfrac12$ and a counted number of oscillations are exact; dividing a timed interval by $20$ oscillations divides the absolute error by $20$ but leaves the percentage error unchanged.
4. A quantity that appears twice. Do not split $\dfrac{R_1R_2}{R_1+R_2}$ or $\dfrac{uv}{u+v}$ into separate pieces; use the reciprocal rule $\dfrac{\Delta R}{R^2}=\dfrac{\Delta R_1}{R_1^2}+\dfrac{\Delta R_2}{R_2^2}$ (Example 6).
5. Zero error and least count. Corrected reading $=$ observed $-$ zero error, with its sign (a negative zero error is added). An error can never be quoted smaller than the least count.
Two resistors, each $(10.0\pm0.2)\ \Omega$, are connected in parallel. The percentage error in the equivalent resistance is
Exercises
Use the maximum-error rules of this section. Round each final error to one significant figure and the value to the same decimal place.
- 1 A metre scale is divided into millimetres. State its least count and write a length read as $23.4\ \text{cm}$ with its error and percentage error.
- 2 On a pair of Vernier callipers $1\ \text{MSD}=1\ \text{mm}$ and $20$ Vernier divisions coincide with $19$ main-scale divisions. Find the least count.
- 3 A screw gauge has pitch $0.5\ \text{mm}$ and $50$ divisions on its circular scale. Find its least count, and the reading when the linear scale shows $3.5\ \text{mm}$ and the $28$th circular division is on the reference line.
- 4 A screw gauge reads $-0.03\ \text{mm}$ when its jaws are closed. A wire then reads $1.52\ \text{mm}$. Find its true diameter.
- 5 Classify each error as systematic or random, and name its source: (a) a stopwatch that runs $1\%$ slow; (b) always reading a scale from slightly above; (c) small, unpredictable differences in when you press a stopwatch; (d) a steel tape used in hot sunshine.
- 6 The true length of a block is $5.40\ \text{cm}$. Student A reads $5.12$, $5.13$, $5.11\ \text{cm}$; student B reads $5.2$, $5.6$, $5.4\ \text{cm}$. Whose set is more precise, and whose mean is more accurate?
- 7 Explain in two sentences why averaging many readings reduces random error but not systematic error.
- 1 The time for $20$ oscillations of a pendulum is measured five times: $39.6$, $40.2$, $39.9$, $40.4$, $39.9\ \text{s}$. Find the mean, the mean absolute error and the percentage error.
- 2 From part 1, write the period of one oscillation with its error. What is its percentage error?
- 3 Find the percentage errors in lengths of $4.0\ \text{cm}$ and $40.0\ \text{cm}$, each measured to $\pm0.1\ \text{cm}$.
- 4 A $250\ \text{g}$ mass is known to $0.4\%$. Find its absolute error.
- 5 A resistor is marked $470\ \Omega$ with a tolerance of $5\%$. Between which values does its resistance lie?
- 6 Vernier callipers (LC $0.01\ \text{cm}$) give $3.27$, $3.29$, $3.28$, $3.27$, $3.29\ \text{cm}$. Write the result with its error.
- 7 A distance of $12.40\ \text{m}$ has a relative error of $0.005$. Write it with its absolute error.
- 8 Which is the more precise measurement: $(2.5\pm0.1)\ \text{m}$ or $(250\pm2)\ \text{m}$?
- 1 $A=(12.5\pm0.2)\ \text{cm}$ and $B=(8.3\pm0.1)\ \text{cm}$. Find $A+B$ and $A-B$ with their errors, and the percentage error of $A-B$.
- 2 The temperature of water rises from $(20.4\pm0.5)\ ^\circ\text{C}$ to $(45.8\pm0.5)\ ^\circ\text{C}$. Find the rise with its error and percentage error.
- 3 A rectangle has $l=(5.0\pm0.1)\ \text{cm}$ and $b=(2.0\pm0.1)\ \text{cm}$. Find its area with its error.
- 4 A voltmeter reads $V=(12.0\pm0.2)\ \text{V}$ and an ammeter $I=(2.50\pm0.05)\ \text{A}$. Find $R=V/I$ with its error.
- 5 $Z=\dfrac{A^4B^{1/3}}{C\,D^{3/2}}$, and the percentage errors in $A$, $B$, $C$, $D$ are $1\%$, $3\%$, $2\%$, $2\%$. Find the percentage error in $Z$.
- 6 The mass and the speed of a body are measured with errors of $2\%$ and $3\%$. Find the maximum percentage error in its kinetic energy.
- 7 The radius of a sphere is $(2.00\pm0.02)\ \text{cm}$. Find its volume with its error.
- 8 The period of a pendulum is $T=2\pi\sqrt{l/g}$. If $l$ has a $2\%$ error and $g$ is exact, what is the percentage error in $T$?
- 9 A ball of mass $(0.250\pm0.005)\ \text{kg}$ moves at $(12.0\pm0.3)\ \text{m/s}$. Find its momentum with its error.
- 1 A pendulum of length $98.0\ \text{cm}$ (measured to $1\ \text{mm}$) makes $50$ oscillations in $100\ \text{s}$, timed with a watch of resolution $0.5\ \text{s}$. Find $g=\dfrac{4\pi^2l}{T^2}$ with its error.
- 2 Find the equivalent resistance, with its error, of $R_1=(4.0\pm0.1)\ \Omega$ and $R_2=(12.0\pm0.3)\ \Omega$ in parallel.
- 3 For a convex lens the object and image distances (magnitudes) are $u=(30.0\pm0.1)\ \text{cm}$ and $v=(60.0\pm0.1)\ \text{cm}$, and $\dfrac1f=\dfrac1u+\dfrac1v$. Find $f$ with its error.
- 4 In a resonance-tube experiment with a $500\ \text{Hz}$ tuning fork, the first two resonance lengths are $l_1=(16.2\pm0.1)\ \text{cm}$ and $l_2=(50.6\pm0.1)\ \text{cm}$, and the speed of sound is $v=2f(l_2-l_1)$. Find $v$ with its error.
- 5 The radius of a sphere is measured with a $1.5\%$ error. Find the percentage errors in its surface area and its volume.
- 6 The area of a square plate is found with a $4\%$ error. What is the percentage error in the measurement of its side?
- 7 (Modelling) The diameter of a wire is about $0.50\ \text{mm}$. Find the percentage error in the diameter and in the cross-sectional area if it is measured with (a) a metre scale (LC $1\ \text{mm}$), (b) Vernier callipers (LC $0.1\ \text{mm}$), (c) a screw gauge (LC $0.01\ \text{mm}$). Which would you use in a Young's modulus experiment?
E1. JEE Main · MCQ A screw gauge has a pitch of $1\ \text{mm}$ and $100$ divisions on its circular scale. With the jaws closed it reads $+0.04\ \text{mm}$. When a wire is placed between the jaws, the linear scale shows $2\ \text{mm}$ and the $63$rd circular division is on the reference line. The diameter of the wire is (A) $2.67\ \text{mm}$ (B) $2.63\ \text{mm}$ (C) $2.59\ \text{mm}$ (D) $2.55\ \text{mm}$
E2. JEE Main · Numerical A physical quantity is given by $X=\dfrac{p^2\,q^{1/2}}{r^3\,s}$. The percentage errors in the measurements of $p$, $q$, $r$ and $s$ are $1.5\%$, $2\%$, $1\%$ and $2\%$. Find the maximum percentage error in $X$. Give the answer to the nearest integer.
E3. JEE Main · MCQ In a simple-pendulum experiment the length is $40.0\ \text{cm}$, measured with a scale of least count $1\ \text{mm}$, and the time for $20$ oscillations is $25.0\ \text{s}$, measured with a watch of resolution $0.1\ \text{s}$. The maximum percentage error in $g=\dfrac{4\pi^2l}{T^2}$ is (A) $0.65\%$ (B) $1.05\%$ (C) $0.80\%$ (D) $0.15\%$
E4. JEE Main · Numerical Two resistors $R_1=(6\pm0.3)\ \Omega$ and $R_2=(12\pm0.24)\ \Omega$ are connected in parallel. Find the maximum percentage error in the equivalent resistance. Give the answer to the nearest integer.
E5. JEE Main · MCQ Five readings of a length taken with Vernier callipers of least count $0.01\ \text{cm}$ are $2.62$, $2.65$, $2.60$, $2.63$ and $2.65\ \text{cm}$. The percentage error, based on the mean absolute error, is closest to (A) $0.6\%$ (B) $0.4\%$ (C) $1.1\%$ (D) $3.0\%$
E6. JEE Main · Numerical In an experiment a quantity is calculated as $Z=\dfrac{(a-b)^2}{c}$, where $a=(25.3\pm0.1)\ \text{cm}$, $b=(20.3\pm0.1)\ \text{cm}$ and $c=(4.00\pm0.08)\ \text{cm}$. Find the maximum percentage error in $Z$. Give the answer to the nearest integer.
Research question. How much does your own reaction time limit a hand-timed measurement — and how many oscillations of a pendulum should you time to get the period to $0.5\%$?
Why it matters. Sprint races, swimming events and industrial stop-watch studies all once relied on hand timing; elite sport switched to electronic timing because a human starting and stopping a watch adds both a random scatter and a systematic delay of the order of a tenth of a second. Medical staff counting a pulse for $15$ seconds instead of a full minute face exactly the same trade-off. The error rules of this section tell you how to beat the problem: time a longer interval and divide.
What to do.
- Measure your reaction time with the ruler-drop test: a partner drops a $30\ \text{cm}$ ruler between your fingers without warning; from the distance $d$ it falls before you catch it, $t=\sqrt{2d/g}$. Repeat ten times; find the mean and the mean absolute error.
- Make a pendulum about $1\ \text{m}$ long. Time $N=1,\ 5,\ 10,\ 20$ and $50$ oscillations, five times for each $N$.
- For each $N$ find the mean period $\bar T$ and its mean absolute error $\Delta\bar T$, and plot the percentage error against $N$.
- From your graph, find the smallest $N$ that gives the period to $0.5\%$, and the resulting percentage error in $g=4\pi^2l/T^2$.
Tools: A $30\ \text{cm}$ ruler, string, a small heavy bob, a metre scale, a phone stopwatch (optionally a phone slow-motion video to check your hand timing).
Hand in: A table of $\bar T\pm\Delta\bar T$ for each $N$, the graph, your reaction-time result, and a one-paragraph recommendation for a school lab sheet: how many oscillations, and why.
Going further. Film the pendulum in slow motion and find $T$ from the frame count. Is there a systematic difference between your hand-timed and video periods? Which of your errors does timing more oscillations reduce, and which does it leave unchanged?
🧪 Self-check quiz
Q1. On a pair of Vernier callipers, $50$ Vernier divisions equal $49$ main-scale divisions of $0.5\ \text{mm}$ each. The least count is
Q2. If $Z=A-B$, the maximum absolute error in $Z$ is
Q3. The momentum of a body of exactly known mass is measured with a $2\%$ error. The maximum percentage error in its kinetic energy $K=\dfrac{p^2}{2m}$ is
Q4. Which error is reduced by repeating a measurement many times and averaging?
Q5. A quantity $x$ is measured with a $6\%$ error. The percentage error in $\sqrt{x}$ is