20.2 Electricity, Optics and Electronics Experiments
The JEE Main experiments in electricity, optics and electronics: resistivity with a metre bridge, Ohm's law, a galvanometer's resistance and figure of merit by half deflection, focal lengths by the u–v method, the i–δ curve of a prism, refractive index with a travelling microscope, diode and Zener characteristics, and telling components apart.
Ask a JEE Main candidate why the null point of a metre bridge should be near the middle, why a galvanometer is shunted to half its deflection, how a convex mirror's focal length can be found when it never forms a real image, or how to tell an LED from a capacitor with a multimeter — and the ones who have thought through the experiments answer in seconds. The paper's experimental questions in electricity, optics and electronics are short, but they test exactly that understanding: which reading goes where, which graph is straight, and what the instrument's own resistance or the bench's index error does to the answer.
This section covers the nine experiments in electricity, optics and electronics in the syllabus, in the same format as Section 20.1: aim, apparatus, method, observation table, graph or calculation, and precautions and sources of error, with the theory linked to the section where it was taught — current electricity in Chapter 12 (12.1, 12.3), the galvanometer in Section 13.2, mirrors, lenses and prisms in 16.1 and 16.2, and semiconductor devices in Chapter 19 (19.1, 19.2).
Resistance experiments: metre bridge, Ohm's law and the galvanometer
All three experiments measure a resistance, each in a different way: by balancing a bridge (no current through the detector, so the meter's own properties drop out), by measuring $V$ and $I$ directly (where the meters' resistances matter), and by halving a deflection (where a large series resistance makes the circuit current nearly constant).
Experiment 1 — Resistivity of the material of a wire using a metre bridge
Aim. To find the resistance of a given wire with a metre bridge and hence the resistivity of its material. Apparatus. Metre bridge, galvanometer, resistance box, the wire, Leclanché cell (or a $2\ \text{V}$ cell), one-way key, jockey, screw gauge, metre scale, connecting wires.
From Section 12.3 (Law 12.16 and Result 12.17), with the known $R$ in the left gap, the wire $X$ in the right gap and the null point at $l$ cm from the left end, $X=R\,(100-l)/l$. Interchanging $R$ and $X$ and averaging removes the end errors.
If the null point is at $l_1$ with $R$ on the left and at $l_2$ (still measured from the left end) after interchanging $R$ and $X$,
$$X_1=R\,\frac{100-l_1}{l_1},\qquad X_2=R\,\frac{l_2}{100-l_2},\qquad X=\tfrac12(X_1+X_2),$$and for a wire of length $L$ and diameter $d$, the resistivity is $\ \rho=\dfrac{\pi d^2X}{4L}$.
Method.
- Connect the wire (its whole measured length $L$ between the terminals) in the right gap and the resistance box in the left gap; the cell and key across the ends of the bridge wire; the galvanometer from the central strip to the jockey.
- Take a resistance $R$ from the box and touch the jockey near each end of the wire: the galvanometer should deflect in opposite directions. Find the null point $l_1$ by gentle touches (never sliding the jockey).
- Choose $R$ so that the null point lies between about $40$ and $60\ \text{cm}$. Repeat for three values of $R$.
- Interchange $R$ and $X$ and repeat to find $l_2$. Measure $L$ with a metre scale and $d$ with a screw gauge (several places, two directions).
| $R$ ($\Omega$) | $l_1$ (cm) | $X_1$ ($\Omega$) | $l_2$ (cm) | $X_2$ ($\Omega$) | mean $X$ ($\Omega$) |
|---|---|---|---|---|---|
| $2.0$ | $40.2$ | $2.975$ | $60.2$ | $3.025$ | $3.00$ |
Precautions and sources of error. Clean and tighten all connections (thick, short copper leads); keep the key closed only while taking a reading (the wire heats and its resistance changes); press the jockey gently and never slide it (it scrapes the wire and spoils its uniformity); keep the null point near the middle, where the error in $X$ is least. End resistances and a non-uniform bridge wire are the main systematic errors — interchanging $R$ and $X$ reduces them.
Experiment 2 — Resistance of a wire using Ohm's law
Aim. To find the resistance of a given wire by plotting a graph of potential difference against current. Apparatus. The wire, battery, rheostat, ammeter, voltmeter, key, connecting wires.
For an ohmic conductor at constant temperature, $V=IR$ (Section 12.1, Law 12.3): the $V$–$I$ graph is a straight line through the origin and $R=\dfrac{\Delta V}{\Delta I}$ is its slope. With the voltmeter (resistance $R_V$) connected directly across the wire, the ammeter also carries the voltmeter's current, so the measured value is
$$R_\text{meas}=\frac{R\,R_V}{R+R_V}\lt R,\qquad R=\frac{R_\text{meas}R_V}{R_V-R_\text{meas}},$$which is close to $R$ only when $R_V\gg R$.
Method.
- Connect the battery, key, rheostat, ammeter and wire in series, and the voltmeter in parallel with the wire (positive terminals towards the positive of the battery).
- Note the least counts and zero errors of both meters.
- Adjust the rheostat to pass a small current; read $I$ and $V$. Increase the current in steps, taking five or six pairs of readings, and open the key between readings.
- Plot $V$ against $I$; find $R$ from the slope (using a large triangle on the line).
| $I$ (A) | $0.10$ | $0.20$ | $0.30$ | $0.40$ |
|---|---|---|---|---|
| $V$ (V) | $0.52$ | $1.04$ | $1.55$ | $2.08$ |
Slope $=\dfrac{2.08-0.52}{0.40-0.10}=5.2\ \Omega$.
Precautions and sources of error. Keep the current small and the key open between readings, so the wire does not heat up (its resistance rises with temperature and the graph curves); use meters of suitable range so the readings lie in the upper part of the scale; check for zero errors. A voltmeter of too low resistance makes $R$ too small (Result 20.11).
Experiment 3 — Resistance and figure of merit of a galvanometer by half deflection
Aim. To find the resistance $G$ of a moving-coil galvanometer by the half-deflection method and its figure of merit. Apparatus. Galvanometer, a cell of steady emf (accumulator), two resistance boxes (a high-resistance box $R$ up to $10\ \text{k}\Omega$ and a low-resistance box $S$), two keys, connecting wires.
The figure of merit $k$ of a galvanometer is the current needed to produce a deflection of one division: $k=I/\theta$, in A/div. It is the reciprocal of the current sensitivity (Section 13.2); a smaller figure of merit means a more sensitive galvanometer.
A cell of emf $E$ (negligible internal resistance) drives a current through a resistance $R$ and the galvanometer $G$ in series, giving a deflection $\theta$. A shunt $S$ is then connected across the galvanometer and adjusted, keeping $R$ fixed, until the deflection is $\theta/2$. Then
$$G=\frac{R\,S}{R-S}\approx S\quad(R\gg S),\qquad k=\frac{E}{(R+G)\,\theta}.$$Derivation. Without the shunt, $I_g=\dfrac{E}{R+G}$. With it, the total current is $\dfrac{E}{R+GS/(G+S)}$ and the galvanometer takes the fraction $\dfrac{S}{G+S}$ of it: $I_g'=\dfrac{ES}{R(G+S)+GS}$. Setting $I_g'=\tfrac12I_g$ gives $2S(R+G)=R(G+S)+GS$, i.e. $G(R-S)=RS$. Because $R$ is thousands of ohms and $S$ tens, connecting $S$ barely changes the circuit current, so half of it in the galvanometer means $S\approx G$ — hence the name.
Method.
- Connect the cell, key $K_1$, the high-resistance box $R$ and the galvanometer in series; connect the low-resistance box $S$ through key $K_2$ across the galvanometer.
- With $K_2$ open, take a large $R$ (several kilo-ohms) and adjust it to give an even-numbered deflection $\theta$ (say $30$ divisions).
- Close $K_2$ and adjust $S$ until the deflection is exactly $\theta/2$. Record $R$, $\theta$ and $S$. Repeat for several values of $R$.
- Calculate $G$ for each set, and $k$ from the first part of each set.
| $R$ ($\Omega$) | $\theta$ (div) | $S$ ($\Omega$) | $G=\dfrac{RS}{R-S}$ ($\Omega$) | $k$ (A/div) |
|---|---|---|---|---|
| $5000$ | $30$ | $50$ | $50.5$ | $1.32\times10^{-5}$ |
Precautions and sources of error. Use a cell of steady emf and negligible internal resistance (an accumulator); keep $R$ much larger than $S$; take even-numbered deflections that are large (for better relative precision); do not change $R$ after closing $K_2$; tighten plugs in the resistance boxes. An internal resistance $r$ of the cell simply adds to $R$.
In the Ohm's-law experiment the voltmeter is connected directly across the wire and the ammeter in series with the pair. Compared with the true resistance of the wire, the value $V/I$ found is
Focal lengths by the u–v method
The optical bench experiments locate images with pins instead of a screen. Their key skill is removing parallax; their theory is the mirror and lens formulas of Section 16.1 (Law 16.5, $\tfrac1v+\tfrac1u=\tfrac1f$) and Section 16.2 (Law 16.11, $\tfrac1v-\tfrac1u=\tfrac1f$), always with the Cartesian sign convention: distances from the pole or optical centre, positive along the direction of the incident light.
Parallax is the apparent relative shift of two objects at different distances when the eye moves sideways. An image pin is at the position of an image when there is no parallax between the tip of the pin and the tip of the image: moving the eye from side to side, the two tips stay together. If they separate, the one that moves with the eye is the farther one, and the pin is moved accordingly.
Concave mirror: $\dfrac1v+\dfrac1u=\dfrac1f$, $\ f=\dfrac{uv}{u+v}$. Convex lens: $\dfrac1v-\dfrac1u=\dfrac1f$, $\ f=\dfrac{uv}{u-v}$. Graphs (in magnitudes, for real images): $\dfrac1{|v|}$ against $\dfrac1{|u|}$ is a straight line of slope $-1$ cutting both axes at $\dfrac1{|f|}$; and the $|u|$–$|v|$ curve is a rectangular hyperbola which the line $|v|=|u|$ meets at $(2|f|,2|f|)$.
Convex mirror (with an auxiliary convex lens): the lens forms a real image $I$ of the object pin. The convex mirror, facing the lens, is placed between the lens and $I$ and moved until the light retraces its path and the image coincides with the object pin. Then $I$ is the mirror's centre of curvature: $R=MI$ (distance from mirror to $I$) and $f=R/2$.
Experiment 4 — Focal length of a concave mirror, a convex lens and a convex mirror
Aim. To find the focal length of a concave mirror and of a convex lens by plotting $u$–$v$ (or $1/u$–$1/v$) graphs, and of a convex mirror using a convex lens. Apparatus. Optical bench with uprights, the mirrors and lens in holders, two optical needles (object and image pins), an index rod, a knitting needle for rough focusing.
Method.
- Rough focal length. Form the image of a distant object (a window) on a wall: the distance from mirror or lens to the image is roughly $|f|$.
- Index correction. Place the index rod between the pole (or optical centre) and the tip of a pin and compare its true length with the difference of the bench readings; the difference is added to every observed distance.
- Concave mirror. Place the object pin beyond $F$ (between $F$ and $2F$, then beyond $2F$). Looking into the mirror, find the inverted image and move the image pin until there is no parallax between their tips. Record the positions; take six or more sets.
- Convex lens. Object pin on one side; look through the lens from the other side for the inverted image, and remove parallax with the image pin.
- Convex mirror. Use a convex lens to form a real image of the object pin and mark its position $I$. Put the convex mirror between lens and $I$ and slide it until the image seen back near the object pin shows no parallax with it. Then $R=$ distance from mirror to the old position of $I$.
| Concave mirror: $u$ (cm) | $-25.0$ | $-30.0$ | $-40.0$ | $-50.0$ |
|---|---|---|---|---|
| $v$ (cm) | $-100.4$ | $-59.6$ | $-40.2$ | $-33.4$ |
| $f=uv/(u+v)$ (cm) | $-20.0$ | $-20.0$ | $-20.0$ | $-20.0$ |
Precautions and sources of error. Align the tips of the pins with the pole (or optical centre) at the same height; remove parallax tip to tip, keeping the eye at least $25\ \text{cm}$ from the pin; apply the index correction; keep the mirror or lens upright and clean. Using only paraxial rays (small apertures) reduces aberration. Readings very close to $F$ give huge, uncertain $v$ and should be avoided.
In Interactive 1 choose the convex lens, set $f=20\ \text{cm}$ and put the object pin $30\ \text{cm}$ from the lens. Where will the image pin show no parallax, and what is the magnification?
In the u–v experiment with a concave mirror, the image pin is moved until "there is no parallax". This means that
The prism and the glass slab
Two experiments measure refractive index: one from the deviation produced by a prism (Section 16.2, Result 16.13), the other from the apparent depth of a mark seen through a slab (Result 16.7), measured with the travelling microscope of Section 20.1.
For a prism of angle $A$, with angle of incidence $i$ and angle of emergence $e$, the deviation is $\delta=i+e-A$. As $i$ increases, $\delta$ falls to a minimum $\delta_m$ and then rises; the curve is not symmetric (it rises more slowly on the large-$i$ side). At the minimum $i=e$, and
$$n=\frac{\sin\frac{A+\delta_m}{2}}{\sin\frac{A}{2}},\qquad i_\text{min}=\frac{A+\delta_m}{2}.$$Every deviation above $\delta_m$ occurs for two angles of incidence, $i$ and $e$ (the path reversed).
Experiment 5 — Angle of deviation against angle of incidence for a prism
Aim. To plot the graph of the angle of deviation against the angle of incidence for a triangular glass prism, and to find its refractive index from the minimum deviation. Apparatus. Equilateral glass prism, drawing board, white sheet, pins, protractor, scale, drawing pins.
Method.
- Fix the sheet on the board and outline the prism, $ABC$. Draw a normal to face $AB$ and a line at the chosen angle of incidence $i$ (start near $35^\circ$).
- Fix two pins $P$, $Q$ on the incident line, at least $5\ \text{cm}$ apart. Looking through face $AC$, fix pins $R$, $S$ in line with the images of $P$ and $Q$.
- Remove the prism, draw the emergent ray $RS$, extend the incident and emergent rays to meet and measure the deviation $\delta$ (and $e$ as a check: $\delta=i+e-A$).
- Repeat for $i$ from about $35^\circ$ to $60^\circ$ in steps of $5^\circ$, with closer steps near the minimum. Plot $\delta$ against $i$; read $\delta_m$.
| $i$ (°) | $35$ | $40$ | $45$ | $48$ | $50$ | $55$ | $60$ |
|---|---|---|---|---|---|---|---|
| $\delta$ (°) | $41.0$ | $38.5$ | $37.4$ | $37.2$ | $37.2$ | $37.7$ | $38.9$ |
Precautions and sources of error. Keep the pins vertical and well separated ($\gt5\ \text{cm}$); look at the feet of the pins' images; use the same base position of the prism for every reading; avoid very small $i$ (no emergence or very faint rays). The minimum is flat, so read $\delta_m$ from a smooth curve, not a single point; pin positions and protractor readings (to $0.5^\circ$) are the main errors.
If the microscope reads $R_1$ when focused on a mark on the base, $R_2$ when focused on the same mark seen through a slab placed over it, and $R_3$ when focused on the top surface of the slab, then real thickness $=R_3-R_1$, apparent thickness $=R_3-R_2$, and
$$n=\frac{\text{real thickness}}{\text{apparent thickness}}=\frac{R_3-R_1}{R_3-R_2},\qquad\text{normal shift }R_2-R_1=t\left(1-\frac1n\right).$$Experiment 6 — Refractive index of a glass slab using a travelling microscope
Aim. To determine the refractive index of a glass slab using a travelling microscope. Apparatus. Travelling microscope, glass slab, a sheet with a fine ink cross (or lycopodium powder), spirit level.
Method.
- Level the microscope base and set the microscope vertical. Find the least count of its vertical scale.
- Focus on the cross mark on the base, eliminating parallax with the cross-wire: reading $R_1$.
- Place the slab over the mark without disturbing it. Raise the microscope (always upwards) to focus the mark seen through the glass: $R_2$.
- Sprinkle a little lycopodium powder on the top surface and raise the microscope to focus on it: $R_3$. Repeat the whole set three times.
| $R_1$ (cm) | $R_2$ (cm) | $R_3$ (cm) | real $R_3-R_1$ (cm) | apparent $R_3-R_2$ (cm) | $n$ |
|---|---|---|---|---|---|
| $4.215$ | $4.795$ | $5.955$ | $1.740$ | $1.160$ | $1.50$ |
Precautions and sources of error. Move the microscope in one direction only (backlash); remove parallax between cross-wire and image at every focus; use a thin layer of powder; the slab should be thick (a thin slab gives a small apparent thickness with a large relative error). The precision is limited by the depth of focus of the microscope.
With a travelling microscope, the readings are $R_1=2.000\ \text{cm}$ on a mark, $R_2=2.400\ \text{cm}$ on the mark seen through a slab, and $R_3=3.200\ \text{cm}$ on the top of the slab. The refractive index is
Diodes and identifying components
The last three experiments are about semiconductor devices (Section 19.1 and Section 19.2). Two plot characteristic curves; the third uses the same one-way behaviour to sort a mixed collection of components.
- Forward bias (p side positive): almost no current until the knee (cut-in) voltage — about $0.7\ \text{V}$ for silicon, $0.3\ \text{V}$ for germanium, $1.6$–$2\ \text{V}$ for a red LED — then a steep rise (milliamperes). The dynamic resistance at a point is $r_d=\dfrac{\Delta V}{\Delta I}$ (inverse slope of the $I$–$V$ curve there).
- Reverse bias: a tiny, nearly constant reverse saturation current (microamperes or less) until breakdown.
- Zener diode, reverse bias: at the breakdown voltage $V_Z$ the reverse current rises sharply while the voltage stays almost constant at $V_Z$; a series resistor $R=\dfrac{V_s-V_Z}{I}$ limits the current.
Experiment 7 — Characteristic curves of a p–n junction diode
Aim. To draw the $I$–$V$ characteristic curves of a p–n junction diode in forward and reverse bias. Apparatus. Diode, $3\ \text{V}$ and $15\ \text{V}$ batteries (or a variable supply), rheostat (as potential divider), milliammeter, microammeter, voltmeters ($0$–$3\ \text{V}$ and $0$–$15\ \text{V}$), key.
Method.
- Forward bias: connect the battery through the potential divider so that the p side is positive; the milliammeter in series and the low-range voltmeter across the diode. Increase $V$ from $0$ in steps of $0.1\ \text{V}$ (smaller steps near the knee) and record $I$ in mA.
- Reverse bias: reverse the diode connections, change to the higher-voltage battery, the microammeter and the high-range voltmeter. Increase the reverse voltage in steps of $1\ \text{V}$ and record $I$ in $\mu\text{A}$ (stay well below the breakdown rating).
- Plot both on one graph, with different current scales for the two quadrants.
| Forward $V$ (V) | $0.0$ | $0.50$ | $0.60$ | $0.65$ | $0.70$ | $0.75$ |
|---|---|---|---|---|---|---|
| $I$ (mA) | $0$ | $0.1$ | $1.0$ | $3.0$ | $8.0$ | $18.0$ |
| Reverse $V$ (V) | $0$ | $-2$ | $-5$ | $-10$ | ||
| $I$ ($\mu$A) | $0$ | $-0.8$ | $-1.0$ | $-1.0$ | ||
Precautions and sources of error. Always include a series resistance (or start from zero with the divider) — a forward-biased diode connected straight across a battery draws a destructive current; do not exceed the maximum forward current or the reverse breakdown voltage; use a milliammeter for forward and a microammeter for reverse readings; take close readings near the knee. The diode warms at high forward current and its curve shifts.
Experiment 8 — Characteristic curve of a Zener diode and its breakdown voltage
Aim. To draw the reverse characteristic of a Zener diode and find its reverse breakdown voltage. Apparatus. Zener diode (e.g. $5.1\ \text{V}$), variable dc supply ($0$–$15\ \text{V}$), series protective resistor (a few hundred ohms), rheostat, voltmeter, milliammeter, key.
Method.
- Connect the supply, rheostat, protective resistor and milliammeter in series with the Zener in reverse bias; voltmeter across the Zener.
- Raise the supply slowly; record the voltage across the Zener and the current. The current stays nearly zero, then rises steeply at $V_Z$ while the voltage hardly changes.
- Plot $I$ against $V$ (reverse quadrant). $V_Z$ is where the curve turns sharply downward (the voltage at which the current begins to rise steeply).
| Reverse voltage across Zener (V) | $2.0$ | $4.0$ | $5.0$ | $5.1$ | $5.2$ |
|---|---|---|---|---|---|
| Reverse current (mA) | $0$ | $0.01$ | $0.5$ | $10$ | $20$ |
Precautions and sources of error. Never omit the protective series resistor; increase the voltage slowly near breakdown; do not exceed the Zener's power rating ($V_ZI$). The breakdown "knee" is not perfectly sharp, so $V_Z$ is read where the curve becomes steep.
Experiment 9 — Identifying a diode, an LED, a resistor and a capacitor
Aim. To identify a diode, an LED, a resistor and a capacitor from a mixed collection of such items. Apparatus. The components, a multimeter (resistance range), or a battery with a bulb or series resistor and an indicator LED.
Connect each two-lead item to the ohmmeter (or the battery–indicator circuit) one way, then with the leads reversed:
| Item | one way | reversed | other sign |
|---|---|---|---|
| resistor | steady finite resistance | the same value | no light, no change with time |
| diode | low resistance (conducts) | very high resistance | does not glow |
| LED | conducts | very high resistance | glows when it conducts |
| capacitor | a brief kick, then very high resistance | the same brief kick, then very high | charging current that dies away |
An item with three or more leads (a transistor) is set aside; it is not among these four.
Method and precautions. Test each item in both directions with the same meter range; watch the meter at the moment of connection (the capacitor's kick lasts only an instant for a small capacitor — use a high resistance range); discharge capacitors by touching their leads together before testing; keep the test current small so the LED and diode are not damaged.
In Interactive 2 choose the Zener diode (5.1 V), set the supply to $-9.0\ \text{V}$ and the series resistance to $500\ \Omega$. What do you expect for the voltage across the Zener and the current?
1. Metre bridge. $X=R(100-l)/l$ with $l$ measured from the end where $R$ is connected. After interchanging, the null point is measured from the same end: $X=Rl_2/(100-l_2)$. The null point should be near the middle.
2. Half deflection. $R$ is kept fixed while the shunt is adjusted; $G=RS/(R-S)$, which is $\approx S$ only because $R\gg S$. The figure of merit uses the deflection without the shunt.
3. Signs on the optical bench. Concave mirror: $f=uv/(u+v)$ with $u,v\lt0$ for real images; convex lens: $f=uv/(u-v)$ with $u\lt0$, $v\gt0$. Using the mirror formula for a lens is the commonest slip.
4. Convex mirror. It cannot be studied alone by the u–v method (its images of real objects are virtual). With the auxiliary lens, $R=$ mirror-to-image distance, $f=R/2$.
5. Diodes. Forward current in mA, reverse in $\mu$A — the two halves of the graph have different scales. Dynamic resistance $\Delta V/\Delta I$ is not $V/I$. A Zener is used in reverse bias and always with a series resistor.
A component tested with a multimeter on a resistance range shows a low resistance one way and a very high resistance when the leads are reversed, and does not glow. It is
Exercises
Use the Cartesian sign convention for mirrors and lenses (distances from the pole or optical centre, positive along the incident light). Take the cells as having negligible internal resistance unless told otherwise.
- 1 With $R=4.0\ \Omega$ in the left gap of a metre bridge, the null point is at $44.0\ \text{cm}$ from the left end. Find the resistance in the right gap.
- 2 The resistance of part 1 is a wire $1.00\ \text{m}$ long and $0.50\ \text{mm}$ in diameter. Find the resistivity of its material.
- 3 With $R=10\ \Omega$ on the left, the null point is at $33.0\ \text{cm}$; after interchanging, it is at $67.4\ \text{cm}$ (both from the left end). Find the mean value of $X$ and $\beta-\alpha$.
- 4 Why should the null point lie near the middle of the wire, and why must the jockey not be slid along the wire?
- 5 Use the $V$–$I$ table of Experiment 2 to find the resistance of the wire. If the wire is $0.50\ \text{m}$ long with diameter $0.32\ \text{mm}$, find its resistivity.
- 6 A voltmeter of resistance $500\ \Omega$ is connected across a $10.0\ \Omega$ resistor in the Ohm's-law circuit. What resistance will $V/I$ give, and what is the percentage error?
- 7 In the half-deflection method, $R=8000\ \Omega$ gives $25$ divisions with a $1.5\ \text{V}$ cell, and a shunt of $80\ \Omega$ halves the deflection. Find $G$ and the figure of merit.
- 8 Why must $R$ be very large compared with $S$ in the half-deflection method?
- 9 A galvanometer of resistance $80\ \Omega$, figure of merit $2.0\times10^{-5}\ \text{A/div}$ and $30$ divisions is to be made into a voltmeter of range $0$–$3.0\ \text{V}$. Find the series resistance.
- 1 For a concave mirror $u=-36.0\ \text{cm}$ and $v=-45.0\ \text{cm}$. Find the focal length.
- 2 For a convex lens $u=-24.0\ \text{cm}$ and $v=+40.0\ \text{cm}$. Find the focal length.
- 3 For a convex lens, the $|u|$–$|v|$ graph meets the line $|v|=|u|$ at $30\ \text{cm}$. Find the focal length.
- 4 The graph of $1/v$ against $1/u$ for a convex lens has $1/v$-intercept $0.050\ \text{cm}^{-1}$. Find $f$ and the slope of the line.
- 5 A convex lens forms a real image $36.0\ \text{cm}$ from it. A convex mirror placed $22.0\ \text{cm}$ from the lens, facing it, sends the light back along its path. Find the focal length of the mirror.
- 6 For a concave mirror the bench gives $u=-30.0\ \text{cm}$ and $v=-60.0\ \text{cm}$, but the index rod shows that every observed distance is $0.2\ \text{cm}$ too small. Find the corrected focal length.
- 7 Explain why the tips of the pin and the image (rather than any other parts) are used to remove parallax, and why readings very close to the focus are avoided.
- 8 A convex lens of focal length $15\ \text{cm}$ is used. What is the least distance between the object pin and the real image pin?
- 1 An equilateral prism gives a minimum deviation of $38^\circ$. Find its refractive index.
- 2 In the $i$–$\delta$ experiment with $A=60^\circ$, a ray incident at $40^\circ$ emerges at $58.5^\circ$. Find the deviation.
- 3 At what angle of incidence does minimum deviation occur for the prism of part 1?
- 4 Explain why every deviation above the minimum is produced by two angles of incidence, and why the curve is not symmetric about its minimum.
- 5 A travelling microscope reads $4.215\ \text{cm}$ on a mark, $4.795\ \text{cm}$ on the mark seen through a slab and $5.955\ \text{cm}$ on the top of the slab. Find the refractive index.
- 6 A mark is viewed through a glass slab $3.00\ \text{cm}$ thick ($n=1.50$). By how much must the travelling microscope be raised, from its focus on the mark without the slab, to refocus on the mark?
- 7 Why is lycopodium powder sprinkled on the top of the slab, and why is a thick slab better than a thin one?
- 1 A diode carries $10\ \text{mA}$ at $0.70\ \text{V}$ and $18\ \text{mA}$ at $0.74\ \text{V}$. Find its dynamic resistance in this range.
- 2 Find the static resistance of the diode of part 1 at $0.74\ \text{V}$.
- 3 A silicon diode passes $0.50\ \mu\text{A}$ at a reverse voltage of $10\ \text{V}$. Find its reverse resistance.
- 4 A $6.2\ \text{V}$ Zener is to carry $20\ \text{mA}$ from a $12\ \text{V}$ supply. Find the series resistance needed.
- 5 Find the power dissipated in the Zener of part 4.
- 6 In Experiment 7, why is a milliammeter used for forward bias but a microammeter for reverse bias, and why is a higher-voltage battery used for reverse bias?
- 7 Four unlabelled two-lead items give these multimeter results — P: $1.2\ \text{k}\Omega$ both ways; Q: low one way, very high the other, glows; R: a brief kick both ways, then very high; S: low one way, very high the other, no glow. Identify them.
- 8 Why does a red LED need about $1.8\ \text{V}$ to conduct while a silicon diode needs only about $0.7\ \text{V}$?
E1. JEE Main · Numerical In the half-deflection method, a galvanometer in series with a resistance of $9900\ \Omega$ and a cell of negligible internal resistance shows a deflection of $40$ divisions. Keeping the series resistance fixed, a shunt of $99\ \Omega$ across the galvanometer reduces the deflection to $20$ divisions. Find the resistance of the galvanometer in ohms. Give the answer to the nearest integer.
E2. JEE Main · MCQ In the u–v experiment with a convex lens, a graph of $1/v$ ($y$-axis) against $1/u$ ($x$-axis) is drawn using the Cartesian sign convention. It is a straight line with (A) slope $-1$ and $y$-intercept $1/f$ (B) slope $+1$ and $y$-intercept $1/f$ (C) slope $+1$ and $y$-intercept $-1/f$ (D) slope $-1$ passing through the origin
E3. JEE Main · Numerical A convex lens forms a real image of an object pin at a distance of $40\ \text{cm}$ from the lens. A convex mirror is placed between the lens and this image, facing the lens, and moved until the final image coincides with the object pin. The mirror is then $16\ \text{cm}$ from the lens. Find the focal length of the convex mirror in cm. Give the answer to the nearest integer.
E4. JEE Main · MCQ A travelling microscope focused on a scratch on a table reads $2.548\ \text{cm}$. A glass slab is placed over the scratch, and the microscope must be raised to $2.802\ \text{cm}$ to see the scratch again; focused on the top of the slab it reads $3.310\ \text{cm}$. The refractive index of the glass is (A) $1.33$ (B) $1.62$ (C) $1.50$ (D) $2.00$
E5. JEE Main · Numerical In an experiment to plot the $i$–$\delta$ curve of an equilateral glass prism, the deviation is found to be least when the angle of incidence is $48^\circ$. If the refractive index of the glass is $n$, find $100n$ to the nearest integer. (Take $\sin48^\circ=0.743$.)
E6. JEE Main · MCQ Four components are tested with a multimeter on a resistance range, each first one way and then with the leads reversed. Which observation is correctly matched? (A) resistor — low resistance one way, very high the other (B) LED — the same resistance both ways, with a glow (C) diode — a brief kick both ways, then very high resistance (D) capacitor — a brief kick both ways, then very high resistance
Research question. Can the forward characteristic of an LED be used to estimate the energy of the photons it emits — and hence Planck's constant — with only a battery, a resistor and a multimeter?
Why it matters. LEDs now light homes, streets and screens worldwide, and their efficiency depends on how closely the electrical energy per electron matches the photon energy. Engineers choose LED materials by their band gaps; the knee voltage you read off an $I$–$V$ curve is a direct, cheap measurement of that gap. The same idea is used in teaching laboratories around the world as a low-cost estimate of $h$.
What to do.
- Take LEDs of three or four colours (infrared, red, yellow, green, blue if available) with known peak wavelengths from their data sheets.
- For each, connect a $1.5$–$6\ \text{V}$ supply through a $1\ \text{k}\Omega$ resistor and a potentiometer; measure the voltage across the LED and the current (with the multimeter's mA range) in small steps from zero up to about $10\ \text{mA}$.
- Plot each forward characteristic and find the knee voltage $V_k$ by extending the straight, steep part of the curve back to the voltage axis.
- Plot $V_k$ against $1/\lambda$. If $eV_k\approx hc/\lambda$, the slope is $hc/e$; find $h$.
- Compare with the accepted value and discuss why the agreement is only rough.
Tools: Assorted LEDs with data sheets, battery or variable supply, $1\ \text{k}\Omega$ resistor, potentiometer, two multimeters (or one used in turn), graph paper or a spreadsheet.
Hand in: The $I$–$V$ curves on one set of axes, a table of $\lambda$ and $V_k$, the $V_k$–$1/\lambda$ graph with its slope, your value of $h$ with an uncertainty, and a short discussion of the sources of error.
Going further. Cool an LED (in a sealed bag in ice water) and warm it gently; how does its knee voltage change with temperature, and what does that say about using it as a thermometer?
🧪 Self-check quiz
Q1. In a metre-bridge experiment, the known resistance is chosen so that the null point lies near the middle of the wire because
Q2. In the half-deflection method the galvanometer resistance is approximately equal to the shunt resistance because
Q3. The focal length of a convex mirror is found using an auxiliary convex lens because
Q4. At the minimum of the $i$–$\delta$ curve of a prism,
Q5. To find the breakdown voltage of a Zener diode, it is connected