7.3 Galvanic Cells, Electrode Potentials and the Nernst Equation
A galvanic cell lets a redox reaction push electrons through a wire instead of swapping them directly. Standard electrode potentials, measured against the hydrogen electrode, tell you which way any cell runs and what voltage it gives; the Nernst equation corrects that voltage for real concentrations and links $E^{\circ}_{cell}$ to the equilibrium constant.
Drop a strip of zinc into blue copper sulphate solution and within minutes the zinc is coated with red-brown copper, the blue colour fades and the beaker becomes slightly warm. Electrons have jumped from zinc atoms to copper ions — a redox reaction of the kind you balanced in Section 7.1 — and all the energy released has been wasted as a little heat. Now put the zinc and the copper sulphate in separate beakers, join them with a wire and a tube of salt solution, and the same reaction drives a current that can light an LED. Every torch battery, pacemaker cell and phone battery works on this idea: keep the oxidation and the reduction apart, and make the electrons travel through an external circuit to get from one to the other.
In this section we build such galvanic cells, learn the shorthand chemists use to describe them, and meet the different kinds of electrodes. We then ask how much "push" each electrode gives. Single electrode potentials cannot be measured on their own, so we compare every electrode with one reference — the standard hydrogen electrode — and arrange the results in the electrochemical series, a table that predicts the direction of thousands of redox reactions. Finally the Nernst equation tells us how the voltage changes with concentration, how a cell runs down, and how the standard cell potential fixes the equilibrium constant. The conduction of ions in solution was treated in Section 7.2; the energy side of cells (Gibbs energy), electrolysis and practical batteries follow in Section 7.4.
Galvanic cells: the Daniell cell, cell notation and types of electrodes
In the direct reaction $\mathrm{Zn(s)+Cu^{2+}(aq)\rightarrow Zn^{2+}(aq)+Cu(s)}$ the electron transfer happens at the surface of the zinc, atom to ion, over a distance of a fraction of a nanometre. Nothing can tap that flow. To get useful electrical work we must separate the two half-reactions in space:
$$\text{oxidation:}\quad \mathrm{Zn(s)\rightarrow Zn^{2+}(aq)+2e^{-}}$$ $$\text{reduction:}\quad \mathrm{Cu^{2+}(aq)+2e^{-}\rightarrow Cu(s)}$$Each half-reaction takes place in its own half-cell (also called an electrode compartment): a conductor dipping into an electrolyte. The electrons released by zinc can then reach the copper ions only by flowing through an external wire.
An electrochemical cell is a pair of electrodes in contact with electrolytes, in which a redox reaction is coupled to the flow of electrons through an external circuit. A galvanic (or voltaic) cell converts the Gibbs energy of a spontaneous redox reaction into electrical work. (A cell in which an external source of electricity drives a non-spontaneous reaction is an electrolytic cell; see Section 7.4.)
- The anode is the electrode at which oxidation occurs. In a galvanic cell it releases electrons into the wire, so it is the negative terminal.
- The cathode is the electrode at which reduction occurs. In a galvanic cell it takes electrons from the wire, so it is the positive terminal.
Electrons flow in the external circuit from anode to cathode; the conventional current flows the other way, from cathode ($+$) to anode ($-$) outside the cell.
The Daniell cell (J. F. Daniell, 1836) is the classic example: a zinc rod in zinc sulphate solution and a copper rod in copper sulphate solution, connected by a wire through a voltmeter and by a salt bridge. With both solutions at $1\ \mathrm{mol\,L^{-1}}$ at $298\ \mathrm{K}$ the voltmeter reads $1.10\ \mathrm{V}$.
Why is the salt bridge needed? As zinc dissolves, the left solution gains $\mathrm{Zn^{2+}}$ ions with no new anions to balance them; as copper is deposited, the right solution loses $\mathrm{Cu^{2+}}$ and is left with surplus $\mathrm{SO_{4}^{2-}}$. Within a fraction of a second the left compartment would become positively charged and the right one negatively charged, and the charge build-up would stop the reaction. The salt bridge lets ions drift to cancel this.
A salt bridge is a tube (usually an inverted U) filled with a concentrated solution of an inert electrolyte — $\mathrm{KCl}$, $\mathrm{KNO_{3}}$ or $\mathrm{NH_{4}NO_{3}}$ — set in a jelly of agar–agar or gelatin, or soaked into a porous plug. It
- completes the circuit: inside the cell the current is carried by ions — anions of the bridge move into the anode compartment and cations into the cathode compartment;
- keeps both solutions electrically neutral, so the reaction can continue;
- prevents the two solutions from mixing (which would let the reaction happen directly) and keeps the small extra potential at the liquid–liquid boundary (the liquid junction potential) to a minimum, because its cation and anion move at nearly equal speeds.
The electrolyte must not react with either solution: a $\mathrm{KCl}$ bridge cannot be used with $\mathrm{Ag^{+}}$ or $\mathrm{Pb^{2+}}$ solutions, which would precipitate the chloride — $\mathrm{KNO_{3}}$ or $\mathrm{NH_{4}NO_{3}}$ is used instead. A porous pot or sintered-glass disc can replace the bridge in simple cells.
Drawing a cell every time is slow, so chemists write it in one line.
- The anode (oxidation) is written on the left and the cathode (reduction) on the right; the electrode metals are at the two ends.
- A single vertical line $|$ marks a boundary between phases (solid–solution, gas–solution, solid–solid).
- A double vertical line $\|$ marks a salt bridge (a liquid junction whose potential is neglected).
- Species in the same phase are separated by commas; concentrations (mol L⁻¹) and gas pressures (bar) go in brackets.
- When neither member of a couple is a conducting solid (gases, two ions in solution), an inert electrode — usually platinum, sometimes graphite — is written at the end: it carries electrons but takes no part in the reaction.
Examples: $\mathrm{Zn(s)\,|\,Zn^{2+}(aq,1\ M)\,\|\,Cu^{2+}(aq,1\ M)\,|\,Cu(s)}$; $\ \mathrm{Pt(s)\,|\,H_{2}(g,1\ bar)\,|\,H^{+}(aq)\,\|\,Ag^{+}(aq)\,|\,Ag(s)}$.
The cell reaction is read off the diagram as oxidation at the left electrode + reduction at the right electrode, with the electrons cancelled. Its emf is defined as $E_{cell}=E_{\text{right}}-E_{\text{left}}$; if that comes out positive the cell runs as written.
Types of electrodes. The Daniell cell uses the simplest kind of electrode, a metal in a solution of its own ions. Many reactions, however, involve gases, two ions of the same element, or a sparingly soluble salt, and each needs a different construction.
Each electrode is described by its reduction half-reaction (the IUPAC convention used throughout this course).
| type | example (electrode) | electrode reaction (as reduction) |
|---|---|---|
| 1. metal – metal ion | $\mathrm{Cu^{2+}(aq)\,|\,Cu(s)}$ | $\mathrm{Cu^{2+}(aq)+2e^{-}\rightarrow Cu(s)}$ |
| 2. gas electrode | $\mathrm{Cl^{-}(aq)\,|\,Cl_{2}(g)\,|\,Pt(s)}$ | $\mathrm{Cl_{2}(g)+2e^{-}\rightarrow 2Cl^{-}(aq)}$ |
| 3. redox (oxidation–reduction) electrode | $\mathrm{Fe^{3+}(aq),Fe^{2+}(aq)\,|\,Pt(s)}$ | $\mathrm{Fe^{3+}(aq)+e^{-}\rightarrow Fe^{2+}(aq)}$ |
| 4. metal – insoluble salt – anion | $\mathrm{Cl^{-}(aq)\,|\,AgCl(s)\,|\,Ag(s)}$ | $\mathrm{AgCl(s)+e^{-}\rightarrow Ag(s)+Cl^{-}(aq)}$ |
- Gas electrodes ($\mathrm{H_{2}}$, $\mathrm{Cl_{2}}$, $\mathrm{O_{2}}$) bubble the gas over platinum (coated with finely divided "platinum black", which adsorbs the gas and speeds up the electrode reaction) dipping into a solution of the ion.
- Redox electrodes have both oxidation states in solution ($\mathrm{Fe^{3+}/Fe^{2+}}$, $\mathrm{MnO_{4}^{-}/Mn^{2+}}$ in acid, $\mathrm{Sn^{4+}/Sn^{2+}}$); the inert wire only exchanges electrons. (Strictly, every electrode is a redox electrode — the name is kept for this type.)
- Metal–insoluble salt electrodes respond to the concentration of the anion: in the silver–silver chloride electrode the potential depends on $[\mathrm{Cl^{-}}]$. The calomel electrode, $\mathrm{Cl^{-}(aq)\,|\,Hg_{2}Cl_{2}(s)\,|\,Hg(l)}$ with $\mathrm{Hg_{2}Cl_{2}(s)+2e^{-}\rightarrow 2Hg(l)+2Cl^{-}(aq)}$, is of this type. Because their potentials are steady and easy to reproduce, these two are the working reference electrodes of laboratories and pH meters.
While a Daniell cell is supplying current, which statement is correct?
Electrode potentials, the hydrogen electrode and the electrochemical series
When a metal dips into a solution of its ions, two opposite processes start: some atoms leave the metal as ions (leaving their electrons behind), and some ions take electrons from the metal and deposit as atoms. Whichever is faster at first charges the metal: zinc in zinc sulphate loses a few ions and becomes slightly negative, copper in copper sulphate gains a few ions and becomes slightly positive. Within microseconds a layer of opposite charge gathers in the solution next to the surface, and a potential difference between the metal and the solution — the electrode potential — settles at a value that brings the two processes into balance.
This single potential cannot be measured on its own: connecting a voltmeter to the solution means dipping in a second conductor, which creates a second electrode with its own potential. Only differences between two electrodes are measurable. The way out is to agree on one reference electrode and give it the value zero.
The standard hydrogen electrode is a platinum electrode coated with platinum black, dipping into an acid solution in which the hydrogen ions are at unit activity (taken as $[\mathrm{H^{+}}]=1\ \mathrm{mol\,L^{-1}}$), with pure hydrogen gas at $1\ \mathrm{bar}$ bubbling over it:
$$\mathrm{Pt(s)\,|\,H_{2}(g,1\ bar)\,|\,H^{+}(aq,1\ M)},\qquad \mathrm{2H^{+}(aq)+2e^{-}\rightleftharpoons H_{2}(g)}.$$By international convention its potential is exactly zero at every temperature: $E^{\circ}_{\mathrm{H^{+}/H_{2}}}=0$.
The standard electrode potential $E^{\circ}$ of an electrode is the emf of a cell in which that electrode, with every species in its standard state, is the right-hand electrode and the SHE is the left-hand electrode:
$$\mathrm{Pt\,|\,H_{2}(g,1\ bar)\,|\,H^{+}(aq,1\ M)\,\|\,M^{n+}(aq,1\ M)\,|\,M(s)},\qquad E_{cell}=E^{\circ}_{\mathrm{M^{n+}/M}}-0 .$$Standard states: solutes at $1\ \mathrm{mol\,L^{-1}}$ (strictly unit activity), gases at $1\ \mathrm{bar}$, solids and liquids pure; values are usually tabulated at $298\ \mathrm{K}$. Because the electrode is written on the right, $E^{\circ}$ refers to the reduction half-reaction, and it is called a standard reduction potential. It is positive if the electrode is the cathode against the SHE (its ions are reduced more readily than $\mathrm{H^{+}}$), and negative if it is the anode.
For example, the cell $\mathrm{Pt\,|\,H_{2}(1\ bar)\,|\,H^{+}(1\ M)\,\|\,Cu^{2+}(1\ M)\,|\,Cu}$ gives $0.34\ \mathrm{V}$ with copper as the positive terminal, so $E^{\circ}_{\mathrm{Cu^{2+}/Cu}}=+0.34\ \mathrm{V}$: copper ions oxidise hydrogen. With zinc instead of copper the voltmeter reads $0.76\ \mathrm{V}$ but zinc is the negative terminal — zinc reduces $\mathrm{H^{+}}$ to hydrogen — so $E^{\circ}_{\mathrm{Zn^{2+}/Zn}}=-0.76\ \mathrm{V}$.
The electromotive force (emf) or cell potential $E_{cell}$ is the potential difference between the two electrodes when no current is drawn from the cell. In terms of reduction potentials,
$$E_{cell}=E_{\text{right}}-E_{\text{left}}=E_{\text{cathode}}-E_{\text{anode}} .$$It must be measured with (almost) zero current — with a potentiometer, in which an opposing known voltage is adjusted until no current flows, or with a digital voltmeter of very high resistance. If a sizeable current flows, part of the emf is lost driving it through the internal resistance of the cell, and the concentrations at the electrode surfaces change; the reading is then a terminal voltage, lower than the emf.
For any cell built from two electrodes whose standard reduction potentials are known,
$$E^{\circ}_{cell}=E^{\circ}_{\text{cathode}}-E^{\circ}_{\text{anode}}=E^{\circ}_{\text{right}}-E^{\circ}_{\text{left}} .$$- Use both values as reduction potentials, exactly as tabulated; do not change the sign of the anode value before subtracting.
- $E^{\circ}$ is an intensive property: multiplying a half-reaction by 2 (to balance electrons) does not change its $E^{\circ}$. $\mathrm{Ag^{+}+e^{-}\rightarrow Ag}$ and $\mathrm{2Ag^{+}+2e^{-}\rightarrow 2Ag}$ both have $E^{\circ}=+0.80\ \mathrm{V}$.
- If $E^{\circ}_{cell}\gt0$ the cell reaction as written is spontaneous under standard conditions (the electrode on the right really is the cathode); if $E^{\circ}_{cell}\lt0$ the reverse reaction is spontaneous.
Measuring every electrode against the SHE gives a single ranked list. The table below gives values used throughout this chapter.
| reduction half-reaction | $E^{\circ}$ / V (298 K) | |
|---|---|---|
| $\mathrm{F_{2}(g)+2e^{-}\rightarrow 2F^{-}(aq)}$ | $+2.87$ | strongest oxidising agents ↑ |
| $\mathrm{MnO_{4}^{-}(aq)+8H^{+}(aq)+5e^{-}\rightarrow Mn^{2+}(aq)+4H_{2}O(l)}$ | $+1.51$ | |
| $\mathrm{Cl_{2}(g)+2e^{-}\rightarrow 2Cl^{-}(aq)}$ | $+1.36$ | |
| $\mathrm{Cr_{2}O_{7}^{2-}(aq)+14H^{+}(aq)+6e^{-}\rightarrow 2Cr^{3+}(aq)+7H_{2}O(l)}$ | $+1.33$ | |
| $\mathrm{O_{2}(g)+4H^{+}(aq)+4e^{-}\rightarrow 2H_{2}O(l)}$ | $+1.23$ | |
| $\mathrm{Br_{2}(l)+2e^{-}\rightarrow 2Br^{-}(aq)}$ | $+1.09$ | |
| $\mathrm{NO_{3}^{-}(aq)+4H^{+}(aq)+3e^{-}\rightarrow NO(g)+2H_{2}O(l)}$ | $+0.97$ | |
| $\mathrm{Ag^{+}(aq)+e^{-}\rightarrow Ag(s)}$ | $+0.80$ | |
| $\mathrm{Fe^{3+}(aq)+e^{-}\rightarrow Fe^{2+}(aq)}$ | $+0.77$ | |
| $\mathrm{I_{2}(s)+2e^{-}\rightarrow 2I^{-}(aq)}$ | $+0.54$ | |
| $\mathrm{Cu^{2+}(aq)+2e^{-}\rightarrow Cu(s)}$ | $+0.34$ | |
| $\mathrm{AgCl(s)+e^{-}\rightarrow Ag(s)+Cl^{-}(aq)}$ | $+0.22$ | |
| $\mathrm{Sn^{4+}(aq)+2e^{-}\rightarrow Sn^{2+}(aq)}$ | $+0.15$ | |
| $\mathrm{2H^{+}(aq)+2e^{-}\rightarrow H_{2}(g)}$ | $0.00$ | reference |
| $\mathrm{Pb^{2+}(aq)+2e^{-}\rightarrow Pb(s)}$ | $-0.13$ | |
| $\mathrm{Sn^{2+}(aq)+2e^{-}\rightarrow Sn(s)}$ | $-0.14$ | |
| $\mathrm{Ni^{2+}(aq)+2e^{-}\rightarrow Ni(s)}$ | $-0.25$ | |
| $\mathrm{Cd^{2+}(aq)+2e^{-}\rightarrow Cd(s)}$ | $-0.40$ | |
| $\mathrm{Fe^{2+}(aq)+2e^{-}\rightarrow Fe(s)}$ | $-0.44$ | |
| $\mathrm{Cr^{3+}(aq)+3e^{-}\rightarrow Cr(s)}$ | $-0.74$ | |
| $\mathrm{Zn^{2+}(aq)+2e^{-}\rightarrow Zn(s)}$ | $-0.76$ | |
| $\mathrm{2H_{2}O(l)+2e^{-}\rightarrow H_{2}(g)+2OH^{-}(aq)}$ | $-0.83$ | |
| $\mathrm{Al^{3+}(aq)+3e^{-}\rightarrow Al(s)}$ | $-1.66$ | |
| $\mathrm{Mg^{2+}(aq)+2e^{-}\rightarrow Mg(s)}$ | $-2.37$ | |
| $\mathrm{Na^{+}(aq)+e^{-}\rightarrow Na(s)}$ | $-2.71$ | |
| $\mathrm{Ca^{2+}(aq)+2e^{-}\rightarrow Ca(s)}$ | $-2.87$ | |
| $\mathrm{K^{+}(aq)+e^{-}\rightarrow K(s)}$ | $-2.93$ | strongest reducing agents ↓ (the metals) |
| $\mathrm{Li^{+}(aq)+e^{-}\rightarrow Li(s)}$ | $-3.04$ |
The list of reduction half-reactions in order of their standard electrode potentials is the electrochemical series. Under standard conditions:
- Oxidising and reducing power. The higher (more positive) $E^{\circ}$, the more readily the oxidised form (left side) is reduced — so the stronger it is as an oxidising agent ($\mathrm{F_{2}}$ is the strongest). The lower (more negative) $E^{\circ}$, the more readily the reduced form (right side) is oxidised — the stronger it is as a reducing agent ($\mathrm{Li}$ is the strongest in water).
- Feasibility of a redox reaction. The oxidised form of a couple oxidises the reduced form of any couple below it: the reaction is feasible when $E^{\circ}_{cell}=E^{\circ}(\text{couple of the oxidant})-E^{\circ}(\text{couple of the reductant})\gt0$.
- Displacement. A metal displaces from solution the ions of any metal with a higher $E^{\circ}$: $\mathrm{Fe}$ displaces $\mathrm{Cu}$ from $\mathrm{CuSO_{4}}$, $\mathrm{Cu}$ displaces $\mathrm{Ag}$ from $\mathrm{AgNO_{3}}$.
- Hydrogen from acids. Metals with negative $E^{\circ}$ (above hydrogen in reactivity) can liberate $\mathrm{H_{2}}$ from dilute non-oxidising acids such as $\mathrm{HCl}$ and dilute $\mathrm{H_{2}SO_{4}}$; metals with positive $E^{\circ}$ (Cu, Ag, Au) cannot. They dissolve only in oxidising acids, where the oxidant is $\mathrm{NO_{3}^{-}}$, not $\mathrm{H^{+}}$.
- The best cell. The emf of a cell made from two couples is the vertical distance between them in the series; the further apart, the larger $E^{\circ}_{cell}$.
Caution: these are predictions of thermodynamic feasibility at standard concentrations. A feasible reaction may still be very slow, and a large change in concentration (Nernst equation, below) can reverse a prediction when $E^{\circ}_{cell}$ is small.
- Split the reaction into its oxidation and reduction half-reactions; identify the oxidising agent and the reducing agent.
- Look up both couples as reduction potentials.
- $E^{\circ}_{cell}=E^{\circ}(\text{oxidant's couple})-E^{\circ}(\text{reductant's couple})$ — "cathode minus anode".
- Positive: feasible as written (and the oxidant's electrode would be the cathode). Negative: the reverse reaction is feasible. Never multiply $E^{\circ}$ by the stoichiometric coefficients.
In the cell builder choose lead for the left electrode and nickel for the right electrode, i.e. $\mathrm{Pb\,|\,Pb^{2+}\,\|\,Ni^{2+}\,|\,Ni}$. What will the voltmeter (reading $E_{\text{right}}-E_{\text{left}}$) show, and what happens?
$E^{\circ}_{\mathrm{Ag^{+}/Ag}}=+0.80\ \mathrm{V}$ and $E^{\circ}_{\mathrm{Cu^{2+}/Cu}}=+0.34\ \mathrm{V}$. For the cell reaction $\mathrm{Cu(s)+2Ag^{+}(aq)\rightarrow Cu^{2+}(aq)+2Ag(s)}$, $E^{\circ}_{cell}$ is
The Nernst equation, concentration cells and the equilibrium constant
A fresh Daniell cell with both solutions at $1\ \mathrm{M}$ gives $1.10\ \mathrm{V}$. As it works, $[\mathrm{Zn^{2+}}]$ rises and $[\mathrm{Cu^{2+}}]$ falls, and the voltage slowly drops — until, when the reaction has reached equilibrium, the cell is "flat" and the emf is zero. Electrode potentials therefore depend on concentration, and in 1889 Walther Nernst gave the exact dependence. (Its thermodynamic derivation, from $\Delta G=\Delta G^{\circ}+RT\ln Q$, is in Section 7.4.)
For an electrode with reduction half-reaction $\mathrm{Ox}+n\mathrm{e^{-}}\rightarrow\mathrm{Red}$ at temperature $T$,
$$E=E^{\circ}-\frac{RT}{nF}\ln\frac{[\mathrm{Red}]}{[\mathrm{Ox}]},$$and, converting to common logarithms with $R=8.314\ \mathrm{J\,mol^{-1}\,K^{-1}}$, $F=96\,487\ \mathrm{C\,mol^{-1}}$ and $T=298\ \mathrm{K}$ ($2.303RT/F=0.059\ \mathrm{V}$),
$$E=E^{\circ}-\frac{0.059}{n}\log\frac{[\mathrm{Red}]}{[\mathrm{Ox}]}\quad(298\ \mathrm{K}).$$Conditions: concentrations in $\mathrm{mol\,L^{-1}}$ stand for activities (exact only in dilute solution); gases enter as partial pressures in bar; pure solids and liquids (the metal, $\mathrm{AgCl(s)}$, $\mathrm{H_{2}O(l)}$) count as $1$. For a metal–ion electrode $\mathrm{M^{n+}+ne^{-}\rightarrow M(s)}$: $$E_{\mathrm{M^{n+}/M}}=E^{\circ}_{\mathrm{M^{n+}/M}}-\frac{0.059}{n}\log\frac{1}{[\mathrm{M^{n+}}]}=E^{\circ}+\frac{0.059}{n}\log[\mathrm{M^{n+}}].$$
Two useful special cases. A metal electrode becomes less positive when its ion is diluted: tenfold dilution of $\mathrm{Cu^{2+}}$ lowers $E$ by $0.059/2=0.0295\ \mathrm{V}$. And for the hydrogen electrode at $1\ \mathrm{bar}$, $\mathrm{2H^{+}+2e^{-}\rightarrow H_{2}}$: $$E_{\mathrm{H^{+}/H_{2}}}=0-\frac{0.059}{2}\log\frac{p_{\mathrm{H_{2}}}}{[\mathrm{H^{+}}]^{2}}=-0.059\,\mathrm{pH}\quad(p_{\mathrm{H_{2}}}=1\ \mathrm{bar}),$$ so a hydrogen electrode measures pH. Only at pH 0 is its potential zero.
For a cell whose balanced reaction transfers $n$ moles of electrons per mole of reaction, $a\mathrm{A}+b\mathrm{B}\rightarrow c\mathrm{C}+d\mathrm{D}$,
$$E_{cell}=E^{\circ}_{cell}-\frac{RT}{nF}\ln Q,$$ $$E_{cell}=E^{\circ}_{cell}-\frac{0.059}{n}\log Q\quad(298\ \mathrm{K}),$$where $Q=\dfrac{[\mathrm{C}]^{c}[\mathrm{D}]^{d}}{[\mathrm{A}]^{a}[\mathrm{B}]^{b}}$ is the reaction quotient of the cell reaction as written (products over reactants, pure solids and liquids omitted, gases as pressures in bar). It follows from Law 7.11 by subtracting the anode equation from the cathode equation, both written for the same $n$. For the Daniell cell ($n=2$):
$$E_{cell}=1.10-\frac{0.059}{2}\log\frac{[\mathrm{Zn^{2+}}]}{[\mathrm{Cu^{2+}}]}\ \mathrm{V}.$$Concentration cells. The Nernst equation predicts something surprising: two electrodes of the same kind, differing only in concentration, also form a cell.
A concentration cell has two electrodes of the same type and material, so that $E^{\circ}_{cell}=0$; its emf arises only from a difference of concentration (of the electrolyte, or of a gas at the electrodes). For a metal–ion concentration cell with $c_{2}\gt c_{1}$,
$$\mathrm{M\,|\,M^{n+}(c_{1})\,\|\,M^{n+}(c_{2})\,|\,M},\qquad E_{cell}=\frac{0.059}{n}\log\frac{c_{2}}{c_{1}}\quad(298\ \mathrm{K}).$$The net change is simply the transfer of $\mathrm{M^{n+}}$ from the concentrated to the dilute solution: metal dissolves at the dilute side (anode) and is deposited at the concentrated side (cathode) until the two concentrations become equal and $E=0$. For a hydrogen concentration cell $\mathrm{Pt\,|\,H_{2}(1\ bar)\,|\,H^{+}(c_{1})\,\|\,H^{+}(c_{2})\,|\,H_{2}(1\ bar)\,|\,Pt}$, $E=0.059\log\dfrac{c_{2}}{c_{1}}$; for a gas concentration cell $\mathrm{Pt\,|\,H_{2}(p_{1})\,|\,H^{+}\,\|\,H^{+}\,|\,H_{2}(p_{2})\,|\,Pt}$, $E=\dfrac{0.059}{2}\log\dfrac{p_{1}}{p_{2}}$ — here the gas at the higher pressure is the anode.
Concentration cells are not just curiosities. The resting potential across a nerve-cell membrane ($\approx -70\ \mathrm{mV}$) is a potassium-ion concentration potential, and a pH meter is in effect a hydrogen-ion concentration cell.
The emf at equilibrium. As a cell discharges, $Q$ grows and $E$ falls. When the cell reaction has reached equilibrium no further work can be obtained: $E_{cell}=0$ and $Q=K$. Putting these into Law 7.12 gives one of the most useful results of the chapter.
At equilibrium $E_{cell}=0$ and $Q=K$, so $0=E^{\circ}_{cell}-\dfrac{RT}{nF}\ln K$:
$$E^{\circ}_{cell}=\frac{RT}{nF}\ln K,$$ $$\log K=\frac{nE^{\circ}_{cell}}{0.059}\quad(298\ \mathrm{K}).$$- $E^{\circ}_{cell}\gt0\Leftrightarrow K\gt1$; $\ E^{\circ}_{cell}=0\Leftrightarrow K=1$; $\ E^{\circ}_{cell}\lt0\Leftrightarrow K\lt1$.
- Because $\log K$ is proportional to $E^{\circ}$, small potentials mean huge constants: with $n=2$, each $0.059\ \mathrm{V}$ multiplies $K$ by $100$. A cell reaction with $E^{\circ}_{cell}$ above about $0.3\ \mathrm{V}$ ($n=2$) goes practically to completion.
- The cell need not be built: any reaction that can be split into two half-reactions with known $E^{\circ}$ — including precipitation and complex formation — has its $K$ fixed this way.
In the Nernst lab choose the Daniell cell and set $\log[\mathrm{Zn^{2+}}]=0$ and $\log[\mathrm{Cu^{2+}}]=-2$ (i.e. $1.0\ \mathrm{M}$ and $0.010\ \mathrm{M}$). What emf do you expect?
1. Flipping the sign twice. $E^{\circ}_{cell}=E^{\circ}_{\text{cathode}}-E^{\circ}_{\text{anode}}$ with both taken as tabulated reduction potentials. If you first rewrite the anode as an oxidation potential (sign changed), you must then add — doing both gives nonsense.
2. Multiplying $E^{\circ}$ by coefficients. $E^{\circ}$ is intensive. Balancing $\mathrm{Ag^{+}+e^{-}\rightarrow Ag}$ to $\mathrm{2Ag^{+}+2e^{-}\rightarrow 2Ag}$ leaves $E^{\circ}=0.80\ \mathrm{V}$. (Coefficients do appear as powers in $Q$, and in $n$.)
3. The wrong $n$ or the wrong $Q$ in the Nernst equation. $n$ is the number of electrons in the balanced overall equation (6 for $\mathrm{2Al+3Cu^{2+}}$), and $Q$ is products over reactants for the reaction as written, without solids. Writing $\dfrac{[\mathrm{Cu^{2+}}]}{[\mathrm{Zn^{2+}}]}$ for the Daniell cell turns a fall in emf into a rise.
4. Concentration cells — which side is the anode? For metal or hydrogen ions the dilute side is the anode; for gases the higher pressure is the anode; for anion electrodes ($\mathrm{Ag\,|\,AgCl\,|\,Cl^{-}}$) the concentrated side is the anode. Write the two Nernst expressions and let the numbers decide.
5. "SHE = 0" is not "every hydrogen electrode = 0". $E_{\mathrm{H^{+}/H_{2}}}=-0.059\,\mathrm{pH}$ at $1\ \mathrm{bar}$; it is zero only at $[\mathrm{H^{+}}]=1\ \mathrm{M}$. And the zero of the SHE is a convention, true at every temperature.
The $\mathrm{CuSO_{4}}$ solution of a working Daniell cell is diluted tenfold (the $\mathrm{ZnSO_{4}}$ is unchanged). At $298\ \mathrm{K}$ the emf
Exercises
Unless stated otherwise take $T=298\ \mathrm{K}$, $2.303RT/F=0.059\ \mathrm{V}$ and the standard potentials in the table of this section (e.g. $\mathrm{Zn}$ $-0.76$, $\mathrm{Fe}$ $-0.44$, $\mathrm{Ni}$ $-0.25$, $\mathrm{Cu}$ $+0.34$, $\mathrm{Ag}$ $+0.80\ \mathrm{V}$).
- 1 For $\mathrm{Al(s)\,|\,Al^{3+}(aq)\,\|\,Cu^{2+}(aq)\,|\,Cu(s)}$ write the electrode reactions and the balanced cell reaction, and give $n$.
- 2 Write the cell diagram for a cell in which $\mathrm{Mg(s)+2H^{+}(aq)\rightarrow Mg^{2+}(aq)+H_{2}(g)}$ takes place.
- 3 Write the cell diagram for $\mathrm{Cl_{2}(g)+2Br^{-}(aq)\rightarrow 2Cl^{-}(aq)+Br_{2}(l)}$ and state which electrode is positive.
- 4 Classify each electrode by type: (i) $\mathrm{Pt\,|\,Cl_{2}(g)\,|\,Cl^{-}(aq)}$; (ii) $\mathrm{Ag\,|\,AgCl(s)\,|\,Cl^{-}(aq)}$; (iii) $\mathrm{Pt\,|\,MnO_{4}^{-},Mn^{2+},H^{+}(aq)}$; (iv) $\mathrm{Ni\,|\,Ni^{2+}(aq)}$.
- 5 A student builds the cell $\mathrm{Cu\,|\,Cu^{2+}\,\|\,Ag^{+}\,|\,Ag}$ with a salt bridge of saturated $\mathrm{KCl}$. What goes wrong? What would you use instead?
- 6 A Daniell cell delivers $0.10\ \mathrm{mol}$ of electrons through its external circuit. Find the change in mass of the zinc rod and of the copper rod ($\mathrm{Zn}=65.4$, $\mathrm{Cu}=63.5$).
- 7 Write the reduction half-reaction of the calomel electrode and of the electrode $\mathrm{Pt\,|\,O_{2}(g)\,|\,H^{+}(aq)}$.
- 8 A voltmeter connected as $\mathrm{Cu\,|\,Cu^{2+}(1\ M)\,\|\,Zn^{2+}(1\ M)\,|\,Zn}$ (reading $E_{\text{right}}-E_{\text{left}}$) shows what value? Which electrode is really the anode?
- 1 Find $E^{\circ}_{cell}$ for $\mathrm{Mg\,|\,Mg^{2+}\,\|\,Ag^{+}\,|\,Ag}$ ($E^{\circ}_{\mathrm{Mg^{2+}/Mg}}=-2.37\ \mathrm{V}$).
- 2 Find $E^{\circ}_{cell}$ for $\mathrm{Pt\,|\,H_{2}(g)\,|\,H^{+}(aq)\,\|\,Cl^{-}(aq)\,|\,Cl_{2}(g)\,|\,Pt}$ under standard conditions.
- 3 Find $E^{\circ}_{cell}$ for a cell based on $\mathrm{2Fe^{3+}(aq)+Sn^{2+}(aq)\rightarrow 2Fe^{2+}(aq)+Sn^{4+}(aq)}$.
- 4 Arrange $\mathrm{Zn}$, $\mathrm{Fe}$, $\mathrm{Ag}$, $\mathrm{Cu}$ and $\mathrm{Mg}$ in order of increasing reducing power.
- 5 Decide, under standard conditions: (i) does nickel dissolve in $1\ \mathrm{M}$ $\mathrm{HCl}$? (ii) does $\mathrm{Fe^{3+}}$ oxidise copper metal? (iii) does iodine oxidise $\mathrm{Fe^{2+}}$?
- 6 A cell $\mathrm{Pt\,|\,H_{2}(1\ bar)\,|\,H^{+}(1\ M)\,\|\,M^{2+}(1\ M)\,|\,M}$ shows an emf of $0.25\ \mathrm{V}$, with M as the negative terminal. Find $E^{\circ}_{\mathrm{M^{2+}/M}}$ and then $E^{\circ}_{cell}$ of $\mathrm{M\,|\,M^{2+}\,\|\,Cu^{2+}\,|\,Cu}$.
- 7 How many of the metals $\mathrm{Al}$, $\mathrm{Cu}$, $\mathrm{Ni}$, $\mathrm{Ag}$ can reduce $\mathrm{Pb^{2+}(aq)}$ to lead under standard conditions ($E^{\circ}_{\mathrm{Pb^{2+}/Pb}}=-0.13\ \mathrm{V}$, $E^{\circ}_{\mathrm{Al^{3+}/Al}}=-1.66\ \mathrm{V}$)?
- 8 From the couples $\mathrm{Ni^{2+}/Ni}$, $\mathrm{Cu^{2+}/Cu}$, $\mathrm{Al^{3+}/Al}$ and $\mathrm{Ag^{+}/Ag}$, which two give the cell of largest emf? Find $E^{\circ}_{cell}$.
- 1 Find the potential of a copper electrode in $0.010\ \mathrm{M}$ $\mathrm{Cu^{2+}}$.
- 2 Find the potential of a hydrogen electrode ($1\ \mathrm{bar}$) in a solution of pH 3.0.
- 3 Find the emf of $\mathrm{Zn\,|\,Zn^{2+}(0.50\ M)\,\|\,Cu^{2+}(0.050\ M)\,|\,Cu}$.
- 4 Find the emf of $\mathrm{Ni\,|\,Ni^{2+}(0.10\ M)\,\|\,Ag^{+}(0.010\ M)\,|\,Ag}$.
- 5 Find the emf of the concentration cell $\mathrm{Ag\,|\,Ag^{+}(0.0010\ M)\,\|\,Ag^{+}(0.10\ M)\,|\,Ag}$.
- 6 The cell $\mathrm{Cu\,|\,Cu^{2+}(c_{1})\,\|\,Cu^{2+}(c_{2})\,|\,Cu}$ has an emf of $0.059\ \mathrm{V}$. Find $c_{2}/c_{1}$.
- 7 Find the emf (in mV) of $\mathrm{Pt\,|\,H_{2}(4.0\ bar)\,|\,H^{+}(1\ M)\,\|\,H^{+}(1\ M)\,|\,H_{2}(1.0\ bar)\,|\,Pt}$.
- 8 At what $[\mathrm{Cu^{2+}}]$ is the potential of a copper electrode $+0.25\ \mathrm{V}$?
- 1 Find $\log K$ and $K$ at $298\ \mathrm{K}$ for $\mathrm{Zn(s)+Cu^{2+}(aq)\rightleftharpoons Zn^{2+}(aq)+Cu(s)}$.
- 2 Find $\log K$ for $\mathrm{2Fe^{3+}(aq)+2I^{-}(aq)\rightleftharpoons 2Fe^{2+}(aq)+I_{2}(s)}$.
- 3 A one-electron cell reaction has $K=1.0\times10^{10}$ at $298\ \mathrm{K}$. Find $E^{\circ}_{cell}$.
- 4 Using $E^{\circ}_{\mathrm{AgCl/Ag}}=+0.22\ \mathrm{V}$, find $-\log K_{sp}$ and $K_{sp}$ of silver chloride.
- 5 The cell $\mathrm{Pt\,|\,H_{2}(1\ bar)\,|\,H^{+}(aq)\,\|\,Ag^{+}(0.10\ M)\,|\,Ag}$ has an emf of $0.977\ \mathrm{V}$. Find the pH of the solution at the anode.
- 6 Zinc is left in $0.10\ \mathrm{M}$ $\mathrm{CuSO_{4}}$ until equilibrium. Using part 1, estimate the $[\mathrm{Cu^{2+}}]$ remaining.
- 7 Find the potential of a platinum wire in a solution with $[\mathrm{Fe^{3+}}]/[\mathrm{Fe^{2+}}]=10$.
- 8 (Applied) To measure the pH of a rainwater sample, a hydrogen electrode ($1\ \mathrm{bar}$) in the sample is connected to a saturated calomel electrode ($E=+0.24\ \mathrm{V}$), which is the cathode. The emf is $0.60\ \mathrm{V}$. Find the pH.
E1. JEE Main · MCQ Given $E^{\circ}_{\mathrm{Cr^{3+}/Cr}}=-0.74\ \mathrm{V}$, $E^{\circ}_{\mathrm{MnO_{4}^{-}/Mn^{2+}}}=1.51\ \mathrm{V}$, $E^{\circ}_{\mathrm{Cr_{2}O_{7}^{2-}/Cr^{3+}}}=1.33\ \mathrm{V}$ and $E^{\circ}_{\mathrm{Cl_{2}/Cl^{-}}}=1.36\ \mathrm{V}$, the strongest reducing agent among the following is (A) $\mathrm{Cl^{-}}$ (B) $\mathrm{Mn^{2+}}$ (C) $\mathrm{Cr}$ (D) $\mathrm{Cr^{3+}}$
E2. JEE Main · Numerical For the cell $\mathrm{Zn(s)\,|\,Zn^{2+}(0.010\ M)\,\|\,Cu^{2+}(1.0\ M)\,|\,Cu(s)}$ with $E^{\circ}_{cell}=1.10\ \mathrm{V}$, find the emf at $298\ \mathrm{K}$ in millivolts ($2.303RT/F=0.059\ \mathrm{V}$). Give the answer to the nearest integer.
E3. JEE Main · MCQ The emf of the cell $\mathrm{Pt\,|\,H_{2}(g,1\ bar)\,|\,HCl(c_{1})\,\|\,HCl(c_{2})\,|\,H_{2}(g,1\ bar)\,|\,Pt}$ is $0.118\ \mathrm{V}$ at $298\ \mathrm{K}$. The ratio $c_{2}/c_{1}$ is (A) $10$ (B) $100$ (C) $1000$ (D) $2$
E4. JEE Main · Numerical For the reaction $\mathrm{Fe(s)+2Fe^{3+}(aq)\rightleftharpoons 3Fe^{2+}(aq)}$, $E^{\circ}_{\mathrm{Fe^{3+}/Fe^{2+}}}=0.77\ \mathrm{V}$ and $E^{\circ}_{\mathrm{Fe^{2+}/Fe}}=-0.44\ \mathrm{V}$. Find $\log K$ at $298\ \mathrm{K}$ ($2.303RT/F=0.059\ \mathrm{V}$). Give the answer to the nearest integer.
E5. JEE Main · MCQ For the Daniell cell at $298\ \mathrm{K}$, a graph of $E_{cell}$ (y-axis) against $\log\dfrac{[\mathrm{Zn^{2+}}]}{[\mathrm{Cu^{2+}}]}$ (x-axis) is (A) a straight line of positive slope through the origin (B) a straight line of slope $-0.059\ \mathrm{V}$ and intercept $1.10\ \mathrm{V}$ (C) a curve that approaches $E=0$ asymptotically (D) a straight line of slope $-0.0295\ \mathrm{V}$ and intercept $1.10\ \mathrm{V}$
E6. JEE Main · Numerical Given $E^{\circ}_{\mathrm{Ag^{+}/Ag}}=0.80\ \mathrm{V}$ and $E^{\circ}_{\mathrm{AgBr/Ag}}=0.07\ \mathrm{V}$ (for $\mathrm{AgBr(s)+e^{-}\rightarrow Ag(s)+Br^{-}(aq)}$) at $298\ \mathrm{K}$, the solubility product of $\mathrm{AgBr}$ is $x\times10^{-13}$. Find $x$ ($2.303RT/F=0.059\ \mathrm{V}$). Give the answer to the nearest integer.
Research question. Do everyday metals in salt water line up in the same order as their standard electrode potentials — and how close do home-made cells come to the predicted voltages?
Why it matters. Ships, offshore platforms, bridges and water pipes join different metals that sit in salt water or wet soil. Marine engineers use a measured "galvanic series" in sea water — not the standard table — to decide which metals may touch, and where to bolt on blocks of zinc or magnesium that are deliberately eaten away to protect a steel hull. Standard potentials assume $1\ \mathrm{M}$ solutions of each metal's own ions, which real sea water is not.
What to do.
- Prepare strips of as many metals as you can find: copper wire, iron nail, galvanised (zinc-coated) nail, aluminium foil, a steel spoon, a brass key, lead fishing weight, a magnesium ribbon if your school laboratory has one.
- Dip a copper strip and one other metal into a glass of $3.5\%$ salt water (sea-water strength) about $2\ \mathrm{cm}$ apart, and read the voltage with a digital multimeter (which draws almost no current). Note which metal is the negative terminal.
- Repeat for every metal against copper, and rank them. Compare your ranking and voltages with the differences of $E^{\circ}$ values from this section.
- Build a Daniell cell properly (zinc in $\mathrm{ZnSO_{4}}$, copper in $\mathrm{CuSO_{4}}$, a strip of filter paper soaked in $\mathrm{KNO_{3}}$ as the bridge) and compare its voltage with $1.10\ \mathrm{V}$. Dilute the $\mathrm{CuSO_{4}}$ tenfold twice and check the Nernst prediction of $-29.5\ \mathrm{mV}$ per step.
Tools: Digital multimeter, crocodile clips, metal strips, table salt, small amounts of $\mathrm{ZnSO_{4}}$, $\mathrm{CuSO_{4}}$ and $\mathrm{KNO_{3}}$ (with a teacher), a spreadsheet.
Hand in: Your measured series in salt water, a table comparing measured and predicted voltages, a plot of the Daniell-cell emf against $\log[\mathrm{Cu^{2+}}]$ with its slope, and a paragraph explaining any metal that is "out of place" (look up passivity and oxide films).
Going further. Aluminium has $E^{\circ}=-1.66\ \mathrm{V}$, yet in salt water it often behaves like a far less reactive metal. Scratch the foil under the water and watch the voltage. What does that tell you about the difference between thermodynamics and what a surface actually does?
🧪 Self-check quiz
Q1. The main function of the salt bridge in a galvanic cell is to
Q2. The standard potential of the hydrogen electrode is zero because
Q3. Using $E^{\circ}$: $\mathrm{Zn^{2+}/Zn}$ $-0.76$, $\mathrm{Fe^{2+}/Fe}$ $-0.44$, $\mathrm{Ni^{2+}/Ni}$ $-0.25$, $\mathrm{Cu^{2+}/Cu}$ $+0.34\ \mathrm{V}$. Which metal reduces $\mathrm{Ni^{2+}}$ but not $\mathrm{Zn^{2+}}$?
Q4. In a Daniell cell at $298\ \mathrm{K}$, $[\mathrm{Zn^{2+}}]$ is increased tenfold while $[\mathrm{Cu^{2+}}]$ is unchanged. The emf
Q5. A cell reaction with $n=2$ has $E^{\circ}_{cell}=0.295\ \mathrm{V}$ at $298\ \mathrm{K}$. Its equilibrium constant is about